Impact of long and short-time voltage variations on the PST and voltage unbalance indicators

O. Murillo, A. Blanco, L. Gallego
{"title":"Impact of long and short-time voltage variations on the PST and voltage unbalance indicators","authors":"O. Murillo, A. Blanco, L. Gallego","doi":"10.1109/ICHQP.2010.5625507","DOIUrl":null,"url":null,"abstract":"Long and short time voltage variations are common electromagnetic phenomena that affect the power quality. According to Colombian resolution CREG 024 of 2005, utilities must register for each system busbar and every 10 minutes, PST values per phase, negative sequence unbalance factor V2/V1, number and duration of the long and short-time voltage variations, number and duration of interruptions involved. In this paper, we present the first results of a proposed new method to find the impact of long and short-time voltage variations on the PST and negative sequence unbalance factor indicators, according to colombian regulations and using real feeders measurements, the proposed method uses basic elements of clustering and data mining.","PeriodicalId":180078,"journal":{"name":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2010.5625507","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Long and short time voltage variations are common electromagnetic phenomena that affect the power quality. According to Colombian resolution CREG 024 of 2005, utilities must register for each system busbar and every 10 minutes, PST values per phase, negative sequence unbalance factor V2/V1, number and duration of the long and short-time voltage variations, number and duration of interruptions involved. In this paper, we present the first results of a proposed new method to find the impact of long and short-time voltage variations on the PST and negative sequence unbalance factor indicators, according to colombian regulations and using real feeders measurements, the proposed method uses basic elements of clustering and data mining.
长、短时电压变化对PST和电压不平衡指标的影响
电压的长、短时变化是影响电能质量的常见电磁现象。根据哥伦比亚2005年的CREG 024号决议,公用事业公司必须登记每一个系统母线和每10分钟,每相PST值,负序不平衡系数V2/V1,长时间和短时间电压变化的次数和持续时间,所涉及的中断次数和持续时间。在本文中,我们提出了一种新的方法来寻找长时间和短时间电压变化对PST和负序不平衡因素指标的影响,根据哥伦比亚法规并使用实际馈线测量,该方法使用聚类和数据挖掘的基本元素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信