{"title":"A simple and practical method for assessing the adequacy of hemodialysis.","authors":"R Soundararajan,&nbsp;P Soundararajan","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The authors plotted the values of the postdialysis/predialysis blood urea nitrogen ratio, R, of 104 functionally anephric maintenance hemodialysis patients against the Kt/V values that had been derived from a single-pool, variable-volume, urea kinetic modeling method. When the R value was less than or equal to 0.4, the Kt/V value was consistently greater than or equal to 1.0. Maintaining an R value below 0.4 would ensure that Kt/V would never be less than 1.0. When a Kt/V value of greater than 1 is desired, an R value of less than 0.4 should be the goal.</p>","PeriodicalId":77493,"journal":{"name":"ASAIO transactions","volume":"37 3","pages":"M393-4"},"PeriodicalIF":0.0000,"publicationDate":"1991-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO transactions","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The authors plotted the values of the postdialysis/predialysis blood urea nitrogen ratio, R, of 104 functionally anephric maintenance hemodialysis patients against the Kt/V values that had been derived from a single-pool, variable-volume, urea kinetic modeling method. When the R value was less than or equal to 0.4, the Kt/V value was consistently greater than or equal to 1.0. Maintaining an R value below 0.4 would ensure that Kt/V would never be less than 1.0. When a Kt/V value of greater than 1 is desired, an R value of less than 0.4 should be the goal.

一种简单实用的血液透析充分性评估方法。
作者绘制了104例功能性无肾维持性血液透析患者透析后/透析前血液尿素氮比R与单池变体积尿素动力学建模方法得出的Kt/V值的对比图。当R值小于等于0.4时,Kt/V值始终大于等于1.0。保持R值低于0.4将确保Kt/V永远不会低于1.0。当期望Kt/V值大于1时,应以R值小于0.4为目标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信