P C Johnson, K O Garrett, H L Borovetz, R L Kormos, J M Armitage, J M Pristas, S Pautler, B P Griffith
{"title":"Thrombin generation in cardiac device recipients.","authors":"P C Johnson, K O Garrett, H L Borovetz, R L Kormos, J M Armitage, J M Pristas, S Pautler, B P Griffith","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Thrombin generation measured after LVAS (4 patients) and TAH (1 patient) implantation was found to be elevated (3 times normal) in the first postoperative week and declined to normal levels when anticoagulation was begun. Thrombin generation was not elevated at the times of thromboembolic events (TIAs; N = 4 episodes).</p>","PeriodicalId":77493,"journal":{"name":"ASAIO transactions","volume":"37 3","pages":"M124-5"},"PeriodicalIF":0.0000,"publicationDate":"1991-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO transactions","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Thrombin generation measured after LVAS (4 patients) and TAH (1 patient) implantation was found to be elevated (3 times normal) in the first postoperative week and declined to normal levels when anticoagulation was begun. Thrombin generation was not elevated at the times of thromboembolic events (TIAs; N = 4 episodes).