{"title":"Improvement of Power Delivery Efficiency of 11KV Power Line using Power Capacitor Placement","authors":"A. Adebimpe, P. Olulope","doi":"10.22161/IJAEMS.4.4.13","DOIUrl":null,"url":null,"abstract":"Optimal capacitor placement in the distribution network is the most popular technique adopted for the control of power loss and enhancement of Volts Ampere Reactive for effective power delivery. This study, therefore, discusses improvement of distribution efficiency of 11kV power lines through placement of capacitor banks in the network. Power flow in the network, Ado-Ekiti 11kV lines, was carried out using Newton-Rapson iteration method available in MATLAB while the analysis of the network was actualized using the conventional load flow equation modeling. From the analysis of the network, voltage deviation falls within the range of -5.9 to -180.5% which is completely outside the permissible range of ±5%. Voltage drop on the feeders is within the range (1.2 – 1.9) kV before and (0.2 – 0.7) kV after the reactive power of the network was compensated.","PeriodicalId":424230,"journal":{"name":"International Journal of Advanced engineering, Management and Science","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Advanced engineering, Management and Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22161/IJAEMS.4.4.13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Optimal capacitor placement in the distribution network is the most popular technique adopted for the control of power loss and enhancement of Volts Ampere Reactive for effective power delivery. This study, therefore, discusses improvement of distribution efficiency of 11kV power lines through placement of capacitor banks in the network. Power flow in the network, Ado-Ekiti 11kV lines, was carried out using Newton-Rapson iteration method available in MATLAB while the analysis of the network was actualized using the conventional load flow equation modeling. From the analysis of the network, voltage deviation falls within the range of -5.9 to -180.5% which is completely outside the permissible range of ±5%. Voltage drop on the feeders is within the range (1.2 – 1.9) kV before and (0.2 – 0.7) kV after the reactive power of the network was compensated.
采用功率电容布置提高11KV输电线的输电效率
配电网中电容器的优化配置是控制功率损耗和提高伏安无功以实现有效输电的最常用技术。因此,本研究讨论通过在网络中放置电容器组来提高11kV电力线的配电效率。采用MATLAB中可用的Newton-Rapson迭代法对Ado-Ekiti 11kV线路网络中的潮流进行了分析,并采用传统的潮流方程建模对网络进行了分析。从网络分析,电压偏差在-5.9 ~ -180.5%的范围内,完全超出了±5%的允许范围。馈线电压降在电网无功补偿前(1.2 ~ 1.9)kV和补偿后(0.2 ~ 0.7)kV范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信