Pulse by pulse current limiting technique for SPWM inverters

Yang Yinfu, Liu Jingbo, Zhou Dangsheng
{"title":"Pulse by pulse current limiting technique for SPWM inverters","authors":"Yang Yinfu, Liu Jingbo, Zhou Dangsheng","doi":"10.1109/PEDS.1999.792848","DOIUrl":null,"url":null,"abstract":"Impactive current overshoot is usually observed in SPWM inverter when impulsive loads are loaded. So far, several methods have been proposed to solve this problem, such as mean current feedback control or temporarily pulling down the voltage reference. Nevertheless, they both have shortcomings. This paper introduces a pulse by pulse current limiting (i.e. instantaneous drive pulse locking) technique which can substantially lessen the impact on SPWM inverter during all kinds of impulsive loading (even the short-circuit of the load). This technique has been used successfully in a 3.5 kW, 400 Hz single-phase full-bridge SPWM inverter. By the pulse by pulse current limiting technique, the successful loading of impulsive loads is ensured, and the loading process has little influence on the normal supply to other important loads which are powered by the inverter at the same time.","PeriodicalId":254764,"journal":{"name":"Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99 (Cat. No.99TH8475)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99 (Cat. No.99TH8475)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDS.1999.792848","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

Impactive current overshoot is usually observed in SPWM inverter when impulsive loads are loaded. So far, several methods have been proposed to solve this problem, such as mean current feedback control or temporarily pulling down the voltage reference. Nevertheless, they both have shortcomings. This paper introduces a pulse by pulse current limiting (i.e. instantaneous drive pulse locking) technique which can substantially lessen the impact on SPWM inverter during all kinds of impulsive loading (even the short-circuit of the load). This technique has been used successfully in a 3.5 kW, 400 Hz single-phase full-bridge SPWM inverter. By the pulse by pulse current limiting technique, the successful loading of impulsive loads is ensured, and the loading process has little influence on the normal supply to other important loads which are powered by the inverter at the same time.
SPWM逆变器的脉冲限流技术
SPWM逆变器在加载脉冲负载时,通常会出现冲击电流超调现象。到目前为止,已经提出了几种方法来解决这个问题,如平均电流反馈控制或暂时拉低电压基准。然而,它们都有缺点。本文介绍了一种脉冲限流(即瞬时驱动锁脉)技术,可以大大减少各种脉冲负载(甚至负载短路)对SPWM逆变器的影响。该技术已成功应用于3.5 kW, 400 Hz单相全桥SPWM逆变器中。通过脉冲逐脉冲限流技术,保证了脉冲负载的顺利加载,且加载过程对同时由逆变器供电的其他重要负载的正常供电影响很小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信