{"title":"Effect of bar material on the biomechanical performance of hybrid dental prosthesis","authors":"Yomna H. Shash, Mohamed M. Dohiem, M. Elwakad, M. Eldosoky","doi":"10.1109/NILES53778.2021.9600489","DOIUrl":null,"url":null,"abstract":"Edentulism is the condition of having no teeth which affects the ability of chewing and reduces the quality of patient's life both physically and psychologically. These problems can be reduced using implant- retained dentures, implant- supported dentures and hybrid prostheses to restore the chewing mechanism. The hybrid prosthesis is suitable for patients suffered bone loss. This prosthesis consists of bar (framework) attached to the copings of the abutments and implants. Acrylic artificial teeth are arranged on the bar and secured with acrylic material. The bar supports the artificial teeth, decreases the number of needed implants and reduces the bone stress. Protocol bars in hybrid prosthesis are usually made of metallic materials such as titanium and gold. The limitations of metal coupled with increasing demands of the patients for metal-free prosthesis led researchers to search for alternatives of metals. Polymers such as PEKK and PEEK have recently been introduced in the dental prostheses to eliminate metallic taste, allergic reactions and the high cost. PEEK properties can be improved by adding others materials such as carbon fibers (CFR-PEEK) or ceramic fillers (Bio-HPP). This paper studies the possibility of using polymers and their composites in the fabrication of bar in hybrid prosthesis as alternative to titanium, by using Finite element model. 3D model of mandible with hybrid prosthesis is constructed and different bar materials (Titanium, CFR-PEEK 30&60%, BIO-HPP, PEKK and PEEK) are stimulated, then the results are extracted and compared together. The simulation results clarify the ability of using the polymers and composites as a bar material. Moreover, CFR-PEEK 60% can be used as alternative to titanium.","PeriodicalId":249153,"journal":{"name":"2021 3rd Novel Intelligent and Leading Emerging Sciences Conference (NILES)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 3rd Novel Intelligent and Leading Emerging Sciences Conference (NILES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NILES53778.2021.9600489","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Edentulism is the condition of having no teeth which affects the ability of chewing and reduces the quality of patient's life both physically and psychologically. These problems can be reduced using implant- retained dentures, implant- supported dentures and hybrid prostheses to restore the chewing mechanism. The hybrid prosthesis is suitable for patients suffered bone loss. This prosthesis consists of bar (framework) attached to the copings of the abutments and implants. Acrylic artificial teeth are arranged on the bar and secured with acrylic material. The bar supports the artificial teeth, decreases the number of needed implants and reduces the bone stress. Protocol bars in hybrid prosthesis are usually made of metallic materials such as titanium and gold. The limitations of metal coupled with increasing demands of the patients for metal-free prosthesis led researchers to search for alternatives of metals. Polymers such as PEKK and PEEK have recently been introduced in the dental prostheses to eliminate metallic taste, allergic reactions and the high cost. PEEK properties can be improved by adding others materials such as carbon fibers (CFR-PEEK) or ceramic fillers (Bio-HPP). This paper studies the possibility of using polymers and their composites in the fabrication of bar in hybrid prosthesis as alternative to titanium, by using Finite element model. 3D model of mandible with hybrid prosthesis is constructed and different bar materials (Titanium, CFR-PEEK 30&60%, BIO-HPP, PEKK and PEEK) are stimulated, then the results are extracted and compared together. The simulation results clarify the ability of using the polymers and composites as a bar material. Moreover, CFR-PEEK 60% can be used as alternative to titanium.
棒状材料对复合义齿生物力学性能的影响
无牙症是一种没有牙齿的疾病,它会影响咀嚼能力,降低患者在生理和心理上的生活质量。这些问题可以通过种植固位义齿、种植支撑义齿和混合义齿修复来减少。混合假体适用于骨质流失患者。这种假体由附着在基台和种植体的覆盖上的杆(框架)组成。压克力假牙设置在杆上,用压克力材料固定。该杆支撑假牙,减少所需种植体数量,减少骨应力。混合假体的协议棒通常由钛和金等金属材料制成。金属的局限性加上患者对无金属假体的需求日益增加,导致研究人员寻找金属的替代品。聚合物如PEKK和PEEK最近被引入到牙科修复体中,以消除金属味,过敏反应和高成本。PEEK的性能可以通过添加其他材料如碳纤维(CFR-PEEK)或陶瓷填料(Bio-HPP)来改善。本文通过有限元模型研究了聚合物及其复合材料替代钛材料制造混合假体棒材的可能性。构建复合修复体下颌骨的三维模型,并对不同材料(钛、CFR-PEEK 30&60%、BIO-HPP、PEKK和PEEK)进行刺激,提取结果并进行比较。仿真结果表明,聚合物和复合材料可以作为棒材材料。此外,60%的CFR-PEEK可以作为钛的替代品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信