G. Kłosowski, T. Rymarczyk, K. Niderla, M. Kulisz, Łukasz Skowron, M. Soleimani
{"title":"Using an LSTM network to monitor industrial reactors using electrical \ncapacitance and impedance tomography – a hybrid approach","authors":"G. Kłosowski, T. Rymarczyk, K. Niderla, M. Kulisz, Łukasz Skowron, M. Soleimani","doi":"10.17531/ein.2023.1.11","DOIUrl":null,"url":null,"abstract":"The article presents a new concept for monitoring industrial tank\nreactors. The presented concept allows for faster and more reliable\nmonitoring of industrial processes, which increases their reliability and\nreduces operating costs. The innovative method is based on electrical\ntomography. At the same time, it is non-invasive and enables the imaging\nof phase changes inside tanks filled with liquid. In particular, the hybrid\ntomograph can detect gas bubbles and crystals formed during industrial\nprocesses. The main novelty of the described solution is the\nsimultaneous use of two types of electrical tomography: impedance and\ncapacitance. Another novelty is the use of the LSTM network to solve\nthe tomographic inverse problem. It was made possible by taking the\nmeasurement vector as a data sequence. Research has shown that the\nproposed hybrid solution and the LSTM algorithm work better than\nseparate systems based on impedance or capacitance tomography.","PeriodicalId":335030,"journal":{"name":"Eksploatacja i Niezawodność – Maintenance and Reliability","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eksploatacja i Niezawodność – Maintenance and Reliability","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17531/ein.2023.1.11","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
The article presents a new concept for monitoring industrial tank
reactors. The presented concept allows for faster and more reliable
monitoring of industrial processes, which increases their reliability and
reduces operating costs. The innovative method is based on electrical
tomography. At the same time, it is non-invasive and enables the imaging
of phase changes inside tanks filled with liquid. In particular, the hybrid
tomograph can detect gas bubbles and crystals formed during industrial
processes. The main novelty of the described solution is the
simultaneous use of two types of electrical tomography: impedance and
capacitance. Another novelty is the use of the LSTM network to solve
the tomographic inverse problem. It was made possible by taking the
measurement vector as a data sequence. Research has shown that the
proposed hybrid solution and the LSTM algorithm work better than
separate systems based on impedance or capacitance tomography.