The use of macro-radiography in the initial examination of the petrous temporal region.

Radiography today Pub Date : 1991-07-01
D Cripps
{"title":"The use of macro-radiography in the initial examination of the petrous temporal region.","authors":"D Cripps","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The results of the survey show that macroradiography of the petrous temporal region is not a common practice. However, the results of the tests show that an increase in discernible detail can be achieved with only a slight increase in geometrical unsharpness, no loss in resolution and, if departmental protocol is to produce AP images through the magnified orbits, a reduction of over 100 times in the radiation exposure dose to the lens of the eye by producing PA macroradiographs instead. Taking into consideration both the image quality of the macro-radiographs obtained, and the radiation exposure dose received by the lens of the eye, the most suitable macroradiographic technique has been implemented within the department as a routine procedure.</p>","PeriodicalId":77602,"journal":{"name":"Radiography today","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1991-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiography today","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The results of the survey show that macroradiography of the petrous temporal region is not a common practice. However, the results of the tests show that an increase in discernible detail can be achieved with only a slight increase in geometrical unsharpness, no loss in resolution and, if departmental protocol is to produce AP images through the magnified orbits, a reduction of over 100 times in the radiation exposure dose to the lens of the eye by producing PA macroradiographs instead. Taking into consideration both the image quality of the macro-radiographs obtained, and the radiation exposure dose received by the lens of the eye, the most suitable macroradiographic technique has been implemented within the department as a routine procedure.

显微x线摄影在颞骨岩区初步检查中的应用。
调查结果表明,显微放射照相的岩颞区是不常见的做法。然而,测试结果表明,可识别细节的增加只会轻微增加几何不清晰度,而不会降低分辨率,如果部门协议是通过放大的轨道产生AP图像,则通过产生PA显微射线照相来减少对眼睛晶状体的辐射暴露剂量100倍以上。考虑到所获得的宏观x线照片的图像质量和眼睛晶状体接受的辐射暴露剂量,最合适的宏观x线摄影技术已在科室内作为常规程序实施。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信