0.25 /spl mu/m CMOS and BiCMOS single-chip direct-conversion Doppler radars for remote sensing of vital signs

A. Droitcour, O. Boric-Lubecke, V. Lubecke, Jenshan Lin
{"title":"0.25 /spl mu/m CMOS and BiCMOS single-chip direct-conversion Doppler radars for remote sensing of vital signs","authors":"A. Droitcour, O. Boric-Lubecke, V. Lubecke, Jenshan Lin","doi":"10.1109/ISSCC.2002.993075","DOIUrl":null,"url":null,"abstract":"A fully integrated direct conversion Doppler radar that detects heart and respiration movement at a distance of 50 cm is described. The 1.6 GHz transceiver is implemented in both CMOS and BiCMOS technologies, with each chip occupying 14 mm/sup 2/ using a 0.25 μm silicon processes. The effects on system sensitivity of phase noise at small offset frequencies with range correlation are assessed.","PeriodicalId":423674,"journal":{"name":"2002 IEEE International Solid-State Circuits Conference. Digest of Technical Papers (Cat. No.02CH37315)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"115","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 IEEE International Solid-State Circuits Conference. Digest of Technical Papers (Cat. No.02CH37315)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISSCC.2002.993075","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 115

Abstract

A fully integrated direct conversion Doppler radar that detects heart and respiration movement at a distance of 50 cm is described. The 1.6 GHz transceiver is implemented in both CMOS and BiCMOS technologies, with each chip occupying 14 mm/sup 2/ using a 0.25 μm silicon processes. The effects on system sensitivity of phase noise at small offset frequencies with range correlation are assessed.
0.25 /spl mu/m CMOS和BiCMOS单片机直接转换多普勒雷达,用于生命体征遥感
描述了一种完全集成的直接转换多普勒雷达,可检测距离为50厘米的心脏和呼吸运动。1.6 GHz收发器采用CMOS和BiCMOS两种技术实现,每个芯片占用14 mm/sup /,采用0.25 μm硅工艺。研究了具有距离相关性的小偏置频率下相位噪声对系统灵敏度的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信