{"title":"Resonance suppression scheme in single-phase grid inverters with LLCL filters","authors":"P. Alemi, Cheol-Ju Bae, Dong-Choon Lee","doi":"10.1109/PEAC.2014.7037907","DOIUrl":null,"url":null,"abstract":"This paper proposes a novel resonance suppression scheme for a single-phase grid inverter with the LLCL filters. In the structure of the LLCL filters, a small inductor is connected in series with the capacitor in the conventional LCL filters to make zero impedance at the switching frequency, by which the grid-side inductor filter can be reduced remarkably. However, since the resonance phenomenon is a critical issue in this case, a new control method using the proportional and resonant (PR) controllers is proposed to damp out the resonance. The simulation results have verified the effectiveness of the proposed control algorithm for a single-phase grid inverter.","PeriodicalId":309780,"journal":{"name":"2014 International Power Electronics and Application Conference and Exposition","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Power Electronics and Application Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEAC.2014.7037907","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

This paper proposes a novel resonance suppression scheme for a single-phase grid inverter with the LLCL filters. In the structure of the LLCL filters, a small inductor is connected in series with the capacitor in the conventional LCL filters to make zero impedance at the switching frequency, by which the grid-side inductor filter can be reduced remarkably. However, since the resonance phenomenon is a critical issue in this case, a new control method using the proportional and resonant (PR) controllers is proposed to damp out the resonance. The simulation results have verified the effectiveness of the proposed control algorithm for a single-phase grid inverter.
带LLCL滤波器的单相电网逆变器谐振抑制方案
提出了一种利用LLCL滤波器抑制单相电网逆变器谐振的新方案。在LLCL滤波器的结构中,将一个小型电感与传统LCL滤波器中的电容串联在一起,使开关频率处的阻抗为零,从而显著减小了电网侧电感滤波器的负载。然而,由于共振现象在这种情况下是一个关键问题,因此提出了一种使用比例和谐振(PR)控制器的新控制方法来抑制谐振。仿真结果验证了所提控制算法对单相并网逆变器控制的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信