Human antibody response to the intravenous and intraperitoneal administration of the F(ab')2 fragment of the OC125 murine monoclonal antibody.

V E Maher, S J Drukman, R J Kinders, R E Hunter, J Jennings, C Brigham, S Stevens, T W Griffin
{"title":"Human antibody response to the intravenous and intraperitoneal administration of the F(ab')2 fragment of the OC125 murine monoclonal antibody.","authors":"V E Maher,&nbsp;S J Drukman,&nbsp;R J Kinders,&nbsp;R E Hunter,&nbsp;J Jennings,&nbsp;C Brigham,&nbsp;S Stevens,&nbsp;T W Griffin","doi":"10.1097/00002371-199201000-00007","DOIUrl":null,"url":null,"abstract":"<p><p>We have characterized the human immune response against murine monoclonal antibodies (HAMA) in 18 patients following administration of the F(ab')2 fragment of the murine monoclonal antibody OC125. OC125 is directed against the CA125 antigen, present on the surface of many human ovarian cancers. An affinity matrix was used to separate serum into immunoglobulin-containing and immunoglobulin-free fractions. HAMA titer was determined on the immunoglobulin fraction with an OC125 sandwich enzyme-linked immunosorbent assay (ELISA). All patients developed an HAMA response, despite the use of F(ab')2 fragments and small amounts (1-4 mg) of antibody. It may be that the intraperitoneal (i.p.) route provides a more marked HAMA response. Enzyme-linked sandwich immunoassays were also used to determine anti-isotype and anti-idiotype titers. Anti-isotype titers were analyzed with antigen irrelevant, isotype-matched murine antibodies and OC125-HRPO. Anti-idiotypes titers were assessed in a sandwich assay that utilized F(ab')2 and F(ab') fragments of OC125. The anti-isotype response tended to be of low titer and short duration, while the anti-idiotype response was of high titer and remarkably persistent. HAMA interfered in an unpredictable manner with the correct measurement of serum levels of CA125 in an enzyme immunoassay using OC125. Corrected values of CA125 could be obtained by measurement of antigen in the immunoglobulin-free fraction of serum. The response of one patient, who developed a markedly elevated anti-idiotype titer after serial i.v./i.p. injections, was further characterized and found to contain an antibody consistent with an anti-anti-idiotype to the CA125 antigen.</p>","PeriodicalId":77209,"journal":{"name":"Journal of immunotherapy : official journal of the Society for Biological Therapy","volume":"11 1","pages":"56-66"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00002371-199201000-00007","citationCount":"22","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of immunotherapy : official journal of the Society for Biological Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/00002371-199201000-00007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22

Abstract

We have characterized the human immune response against murine monoclonal antibodies (HAMA) in 18 patients following administration of the F(ab')2 fragment of the murine monoclonal antibody OC125. OC125 is directed against the CA125 antigen, present on the surface of many human ovarian cancers. An affinity matrix was used to separate serum into immunoglobulin-containing and immunoglobulin-free fractions. HAMA titer was determined on the immunoglobulin fraction with an OC125 sandwich enzyme-linked immunosorbent assay (ELISA). All patients developed an HAMA response, despite the use of F(ab')2 fragments and small amounts (1-4 mg) of antibody. It may be that the intraperitoneal (i.p.) route provides a more marked HAMA response. Enzyme-linked sandwich immunoassays were also used to determine anti-isotype and anti-idiotype titers. Anti-isotype titers were analyzed with antigen irrelevant, isotype-matched murine antibodies and OC125-HRPO. Anti-idiotypes titers were assessed in a sandwich assay that utilized F(ab')2 and F(ab') fragments of OC125. The anti-isotype response tended to be of low titer and short duration, while the anti-idiotype response was of high titer and remarkably persistent. HAMA interfered in an unpredictable manner with the correct measurement of serum levels of CA125 in an enzyme immunoassay using OC125. Corrected values of CA125 could be obtained by measurement of antigen in the immunoglobulin-free fraction of serum. The response of one patient, who developed a markedly elevated anti-idiotype titer after serial i.v./i.p. injections, was further characterized and found to contain an antibody consistent with an anti-anti-idiotype to the CA125 antigen.

人抗体对静脉和腹腔注射OC125小鼠单克隆抗体F(ab’)2片段的反应。
我们描述了18例患者在给予小鼠单克隆抗体OC125的F(ab’)2片段后对小鼠单克隆抗体(HAMA)的免疫反应。OC125靶向存在于许多人卵巢癌表面的CA125抗原。用亲和基质将血清分离为含免疫球蛋白和不含免疫球蛋白两部分。用OC125夹心酶联免疫吸附试验(ELISA)测定免疫球蛋白部分的HAMA滴度。尽管使用了F(ab’)2片段和少量(1-4 mg)抗体,但所有患者均出现了HAMA反应。这可能是腹腔内(i.p.)途径提供更明显的HAMA反应。酶联三明治免疫测定法也用于测定抗同型和抗独特型滴度。用抗原无关、同型匹配的小鼠抗体和OC125-HRPO分析抗同型滴度。利用OC125的F(ab’)2和F(ab’)片段,采用夹心法测定抗独特型滴度。抗同型反应倾向于低滴度和短时间,而抗独特型反应则倾向于高滴度和显著的持久性。在使用OC125的酶免疫测定中,HAMA以不可预测的方式干扰了CA125血清水平的正确测量。CA125的校正值可以通过测定血清中无免疫球蛋白部分的抗原得到。一名患者在连续静脉注射后抗独特型滴度明显升高。进一步表征并发现含有与CA125抗原的抗-抗独特型一致的抗体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信