{"title":"Preliminary studies into high velocity transverse blood flow measurement","authors":"H. Routh, T. Pusateri, D. D. Waters","doi":"10.1109/ULTSYM.1990.171621","DOIUrl":null,"url":null,"abstract":"The design, fabrication and operation of a 4.5-MHz dual-beam probe capable of high-velocity blood flow measurement with a good lateral resolution is described. The authors describe an aluminum lens which is used to generate two adjacent focal spots at a focal length in the range of 30 mm to 80 mm, making it suitable for in vivo blood velocity measurements. The limits on the maximum velocity detectable with this system are dependent on the separation of the two spots and the pulse repetition frequency (PRF). A comparison between simulated PRFs and the measured lens characteristics at different focal lengths is discussed. A possible extension of the technique to three-dimensional velocity measurements is discussed.<<ETX>>","PeriodicalId":412254,"journal":{"name":"IEEE Symposium on Ultrasonics","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Symposium on Ultrasonics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1990.171621","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22

Abstract

The design, fabrication and operation of a 4.5-MHz dual-beam probe capable of high-velocity blood flow measurement with a good lateral resolution is described. The authors describe an aluminum lens which is used to generate two adjacent focal spots at a focal length in the range of 30 mm to 80 mm, making it suitable for in vivo blood velocity measurements. The limits on the maximum velocity detectable with this system are dependent on the separation of the two spots and the pulse repetition frequency (PRF). A comparison between simulated PRFs and the measured lens characteristics at different focal lengths is discussed. A possible extension of the technique to three-dimensional velocity measurements is discussed.<>
高速横向血流测量的初步研究
描述了一种具有良好横向分辨率的高速血流测量4.5 mhz双波束探头的设计、制造和操作。作者描述了一种铝制透镜,用于在30毫米至80毫米的焦距范围内产生两个相邻的焦点,使其适合体内血流速度测量。该系统可检测到的最大速度限制取决于两点的距离和脉冲重复频率(PRF)。讨论了在不同焦距下模拟PRFs与实测值的比较。讨论了将该技术推广到三维速度测量的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信