Evaluation of the Influence of Three Types of Light Curing Systems On Temperature Rise, Depth of Cure and Degree of Conversion of Three Resin Based Composites (An In vitro study)

N. Ghareeb, R. Dayem, J. Kamel, Salam D Al Qaisi
{"title":"Evaluation of the Influence of Three Types of Light Curing Systems On Temperature Rise, Depth of Cure and Degree of Conversion of Three Resin Based Composites (An In vitro study)","authors":"N. Ghareeb, R. Dayem, J. Kamel, Salam D Al Qaisi","doi":"10.4172/2376-032X.1000110","DOIUrl":null,"url":null,"abstract":"Aim of study: The purpose of this study was to evaluate the effect of Quartz tungsten halogen, Light emitted diode & soft start light curing units on temperature rise, depth of cure & degree of conversion of different types of dental composites (Spectrum, Esthet X & Z250). Methodology: Thirty sound, single–rooted human bicuspids extracted for orthodontic purpose were used to measure the temperature rise inside the pulp chamber by using a needle probe, connected to thermocouple thermometer through the apical foramen. Ninety specimens of dental composites (Spectrum, Esthet X & Z250) were prepared by using special mold to determine the depth of cure of different light curing modes (Quartz tungsten halogen, Light emitted diode & soft start) by using the scraping method described by ISO standard for polymer –based filling restorative & luting materials. For the assessment of the degree of conversion, eighteen samples of dental composites were tested by the Fourier – transformed infrared spectrometry according to the standard baseline technique of Rueggeberg et al., 1990. Result and Conclusion: QTH light curing showed the highest temperature rise value, while the soft start gave the lowest values. Soft start light curing revealed the highest depth of cure values, while the QTH showed the lowest values among three curing modes. There were overall statistical significant differences in the depth of cure values among groups of different curing systems & types of dental composites. Soft start light curing system showed the highest degree of conversion and QTH had the lowest values. Esthet X dental composite gave the highest results of the degree of conversion while Z250 showed the lowest values.","PeriodicalId":110010,"journal":{"name":"JBR Journal of Interdisciplinary Medicine and Dental Science","volume":"2014 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JBR Journal of Interdisciplinary Medicine and Dental Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2376-032X.1000110","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Aim of study: The purpose of this study was to evaluate the effect of Quartz tungsten halogen, Light emitted diode & soft start light curing units on temperature rise, depth of cure & degree of conversion of different types of dental composites (Spectrum, Esthet X & Z250). Methodology: Thirty sound, single–rooted human bicuspids extracted for orthodontic purpose were used to measure the temperature rise inside the pulp chamber by using a needle probe, connected to thermocouple thermometer through the apical foramen. Ninety specimens of dental composites (Spectrum, Esthet X & Z250) were prepared by using special mold to determine the depth of cure of different light curing modes (Quartz tungsten halogen, Light emitted diode & soft start) by using the scraping method described by ISO standard for polymer –based filling restorative & luting materials. For the assessment of the degree of conversion, eighteen samples of dental composites were tested by the Fourier – transformed infrared spectrometry according to the standard baseline technique of Rueggeberg et al., 1990. Result and Conclusion: QTH light curing showed the highest temperature rise value, while the soft start gave the lowest values. Soft start light curing revealed the highest depth of cure values, while the QTH showed the lowest values among three curing modes. There were overall statistical significant differences in the depth of cure values among groups of different curing systems & types of dental composites. Soft start light curing system showed the highest degree of conversion and QTH had the lowest values. Esthet X dental composite gave the highest results of the degree of conversion while Z250 showed the lowest values.
三种光固化体系对三种树脂基复合材料温升、固化深度和转化率影响的评价(体外研究)
研究目的:本研究的目的是评价石英钨卤、发光二极管和软启动光固化单元对不同类型牙科复合材料的温升、固化深度和转化程度的影响(Spectrum、Esthet X和Z250)。方法:取30颗正常、单根的人牙髓二尖牙,通过牙髓根尖孔与热电偶温度计连接,用探针测量牙髓腔内的温升。采用聚合物基填充修复修复材料ISO标准所描述的刮擦法,利用专用模具,测定不同光固化方式(石英钨卤、发光二极管和软启动)的固化深度,制备牙科复合材料(Spectrum、Esthet X和Z250) 90个样品。为了评估转化程度,根据Rueggeberg等人1990年的标准基线技术,对18个牙科复合材料样品进行傅里叶变换红外光谱测试。结果与结论:QTH光固化的温升值最高,软启动的温升值最低。软启动光固化的固化深度最高,QTH固化的固化深度最低。不同固化体系和类型牙体复合材料组间的固化深度值总体差异有统计学意义。软启动光固化体系的转化率最高,QTH最低。Esthet X牙科复合材料的转化度最高,Z250最低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信