{"title":"Design and Simulation High Pass Filter Second Order and C-Type Filter for Reducing Harmonics as Power Quality Repair Effort in the Automotive Industry","authors":"Mochamad Irlan Malik, E. Ihsanto","doi":"10.51662/jiae.v3i1.79","DOIUrl":null,"url":null,"abstract":"Electrical distribution is one of the most important parameters in industrial processes. Therefore, good power quality is needed as a supply to industrial machines. The use of industrial machines has an impact on the emergence of harmonics. As a result of the large Harmonics, the quality of power is getting worse, affecting productivity in the industry. Therefore, samples were taken using a Power Quality Analyzer on an 800 kVA transformer on the secondary side of the transformer to maximise the supply of electricity to consumers. Then obtained THDi Phase L1 of 23.1%, phase L2 of 24.7% and phase L3 of 21% and IHDi on the 5th order in phase L1 18.3%, phase L2 20.7% and phase L3 16.6% regarding (IEEE Std 3002.8-2018) and (SPLN D5.004-1:2012) the IHDi value should not be more than 7%. Then simulated using MATLAB/Simulink by designing the Second Order High Pass Filter and C-Type Filter. The results obtained by combining the two filters gained THDi results in the L1 phase at 2.53%, the L2 phase at 2.69% and the L3 phase at 2.22% and the IHDi at the 5th order of the L1 phase at 1.48%, the L2 phase 1.62% and L3 phase 1.33%.","PeriodicalId":424190,"journal":{"name":"Journal of Integrated and Advanced Engineering (JIAE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Integrated and Advanced Engineering (JIAE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51662/jiae.v3i1.79","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Electrical distribution is one of the most important parameters in industrial processes. Therefore, good power quality is needed as a supply to industrial machines. The use of industrial machines has an impact on the emergence of harmonics. As a result of the large Harmonics, the quality of power is getting worse, affecting productivity in the industry. Therefore, samples were taken using a Power Quality Analyzer on an 800 kVA transformer on the secondary side of the transformer to maximise the supply of electricity to consumers. Then obtained THDi Phase L1 of 23.1%, phase L2 of 24.7% and phase L3 of 21% and IHDi on the 5th order in phase L1 18.3%, phase L2 20.7% and phase L3 16.6% regarding (IEEE Std 3002.8-2018) and (SPLN D5.004-1:2012) the IHDi value should not be more than 7%. Then simulated using MATLAB/Simulink by designing the Second Order High Pass Filter and C-Type Filter. The results obtained by combining the two filters gained THDi results in the L1 phase at 2.53%, the L2 phase at 2.69% and the L3 phase at 2.22% and the IHDi at the 5th order of the L1 phase at 1.48%, the L2 phase 1.62% and L3 phase 1.33%.