Platelet preservation during cardiopulmonary bypass with iloprost and Duraflo-II heparin-coated surfaces.

ASAIO transactions Pub Date : 1991-10-01
G M Palatianos, M K Dewanjee, W Smith, S Novak, L C Hsu, M Kapadvanjwala, G N Sfakianakis, G A Kaiser
{"title":"Platelet preservation during cardiopulmonary bypass with iloprost and Duraflo-II heparin-coated surfaces.","authors":"G M Palatianos,&nbsp;M K Dewanjee,&nbsp;W Smith,&nbsp;S Novak,&nbsp;L C Hsu,&nbsp;M Kapadvanjwala,&nbsp;G N Sfakianakis,&nbsp;G A Kaiser","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>To test the hypothesis that temporary platelet inhibition during cardiopulmonary bypass (CPB) with surface heparinized systems may result in platelet preservation, nine Yorkshire pigs were placed on CPB for 3 hours. Platelet labeling was done in all pigs with Indium-111 tropolone. CPB was instituted with a roller pump, a hollow fiber membrane oxygenator (Bentley CM-50 [Baxter-Bentley Laboratories, Irvine, CA]), and an arterial filter. The extracorporeal perfusion systems were surface-coated with the Duraflo-II heparin complex. Group A pigs (n = 5) were systemically heparinized (activated coagulation time longer than 400 sec). Group B pigs (n = 4) were placed on CPB without systematic heparinization, but have received the stable prostacyclin-analog Iloprost (ZK36374) at 1 ng/kg/min i.v. from 30 min before and during CPB. Platelet counts declined in group A pigs at 5 min, 1 hr, 2 hr, and 3 hr of CPB to 79.8% (mean), 66.5%, 71.3%, and 69.0% of pre-CPB values, respectively (p less than 0.05). In group B pigs, mean platelet count during CPB was higher than 90% of control value. Percentage of injected radioactivity detected in the oxygenator was 2.82% in group A pigs versus 0.73% in group B pigs (p = 0.0541). Surface heparinization with the Duraflo II heparin coating complex in combination with Iloprost-induced temporary platelet inhibition resulted in platelet count preservation during CPB in the pig model.</p>","PeriodicalId":77493,"journal":{"name":"ASAIO transactions","volume":"37 4","pages":"620-2"},"PeriodicalIF":0.0000,"publicationDate":"1991-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO transactions","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To test the hypothesis that temporary platelet inhibition during cardiopulmonary bypass (CPB) with surface heparinized systems may result in platelet preservation, nine Yorkshire pigs were placed on CPB for 3 hours. Platelet labeling was done in all pigs with Indium-111 tropolone. CPB was instituted with a roller pump, a hollow fiber membrane oxygenator (Bentley CM-50 [Baxter-Bentley Laboratories, Irvine, CA]), and an arterial filter. The extracorporeal perfusion systems were surface-coated with the Duraflo-II heparin complex. Group A pigs (n = 5) were systemically heparinized (activated coagulation time longer than 400 sec). Group B pigs (n = 4) were placed on CPB without systematic heparinization, but have received the stable prostacyclin-analog Iloprost (ZK36374) at 1 ng/kg/min i.v. from 30 min before and during CPB. Platelet counts declined in group A pigs at 5 min, 1 hr, 2 hr, and 3 hr of CPB to 79.8% (mean), 66.5%, 71.3%, and 69.0% of pre-CPB values, respectively (p less than 0.05). In group B pigs, mean platelet count during CPB was higher than 90% of control value. Percentage of injected radioactivity detected in the oxygenator was 2.82% in group A pigs versus 0.73% in group B pigs (p = 0.0541). Surface heparinization with the Duraflo II heparin coating complex in combination with Iloprost-induced temporary platelet inhibition resulted in platelet count preservation during CPB in the pig model.

体外循环中伊洛前列素和durafo - ii肝素包被表面的血小板保存。
为了验证表面肝素化系统在体外循环(CPB)期间暂时抑制血小板可能导致血小板保存的假设,9只约克郡猪被放置在CPB上3小时。用铟-111 tropolone对所有猪进行血小板标记。CPB采用滚柱泵、中空纤维膜氧合器(Bentley CM-50 [Baxter-Bentley Laboratories, Irvine, CA])和动脉过滤器。体外灌注系统表面涂有Duraflo-II肝素复合物。A组猪(n = 5)全身肝素化(激活凝血时间大于400秒)。B组猪(n = 4)不进行系统性肝素化,但在CPB前30分钟和CPB期间以1 ng/kg/min静脉滴注稳定的前列环素类似物Iloprost (ZK36374)。A组猪在CPB 5 min、1 hr、2 hr和3 hr时血小板计数分别下降至CPB前的79.8%(平均)、66.5%、71.3%和69.0% (p < 0.05)。B组猪CPB期间平均血小板计数高于对照组的90%。氧合器中检测到注射放射性的比例,A组为2.82%,B组为0.73% (p = 0.0541)。在猪CPB模型中,Duraflo II肝素包被复合物的表面肝素化与iloprost诱导的暂时性血小板抑制联合导致血小板计数保持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信