{"title":"Design and control of a three-phase active rectifier under non-ideal operating conditions","authors":"Marco Liserre, A. Dell'Aquila, F. Blaabjerg","doi":"10.1109/IAS.2002.1042708","DOIUrl":null,"url":null,"abstract":"Industrial engineers face many nonideal operating conditions in the design of the active rectifiers: too long computation time, presence of acquisition filters, AC phases unbalance, location of the grid voltage sensors after a dominant reactance and passive damping if an LCL-filter is used. The phenomena generated by these conditions are generally nonlinear. Hence the first step is to find out how much each of them affects the system's overall performance. Then new rules for the tuning of the controllers can be developed on the basis of the analysis of the transient behavior and of the steady state harmonic content of the DC voltage and of the AC current. This procedure is developed in this paper through simulations and laboratory tests.","PeriodicalId":202482,"journal":{"name":"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"41","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2002.1042708","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 41

Abstract

Industrial engineers face many nonideal operating conditions in the design of the active rectifiers: too long computation time, presence of acquisition filters, AC phases unbalance, location of the grid voltage sensors after a dominant reactance and passive damping if an LCL-filter is used. The phenomena generated by these conditions are generally nonlinear. Hence the first step is to find out how much each of them affects the system's overall performance. Then new rules for the tuning of the controllers can be developed on the basis of the analysis of the transient behavior and of the steady state harmonic content of the DC voltage and of the AC current. This procedure is developed in this paper through simulations and laboratory tests.
非理想工况下三相有源整流器的设计与控制
工业工程师在设计有源整流器时面临许多不理想的工作条件:计算时间太长,存在采集滤波器,交流相位不平衡,电网电压传感器在主电抗之后的位置以及如果使用lcl滤波器则存在无源阻尼。这些条件产生的现象通常是非线性的。因此,第一步是找出它们对系统整体性能的影响程度。然后在分析直流电压和交流电流的暂态行为和稳态谐波含量的基础上,制定新的控制器的整定规则。本文通过仿真和实验室试验开发了该程序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信