Comparison of the Effectiveness of the Methods of Recording Physiological Signals Using Passive Electronic Sensors to Obtain Respiratory Parameters in People with Respiratory Dysfunction

Ilona Karpiel, J. Woloszyn, Kamil Olesz, Maciej Mysinski, Mirella Urzeniczok, Daniel Feige, A. Sobotnicki, Marek Czerw
{"title":"Comparison of the Effectiveness of the Methods of Recording Physiological Signals Using Passive Electronic Sensors to Obtain Respiratory Parameters in People with Respiratory Dysfunction","authors":"Ilona Karpiel, J. Woloszyn, Kamil Olesz, Maciej Mysinski, Mirella Urzeniczok, Daniel Feige, A. Sobotnicki, Marek Czerw","doi":"10.23919/MIXDES52406.2021.9497647","DOIUrl":null,"url":null,"abstract":"The purpose of the work is to developed two sensors, based on piezoelectric and resistive elements, used to measure the respiratory signal from the thorax. As a result two innovative methods of monitoring respiratory parameters and cough incidents for patients with respiratory failure, caused by asthma or covid-19. The first sensor was made of the piezoelectric membrane, and the second uses conductive elastic rubber that changes its resistance when stretched. Both sensors were placed on the patient’s chest using a specially designed for this purpose belt.Simultaneous biomedical signals were recorded in laboratory conditions for various measurement methods, which showed chest movement during breathing in healthy people with the simulation of difficult measurement conditions, such as shallow and rapid breathing, slow deep breathing combined with apnea, and in the presence of motor disturbances. The obtained results for both measurement methods allow confirming a satisfactory immunity to movement disturbances and correct detection in extreme measurement conditions such as fast and shallow breathing and apnea while the piezoelectric method, enables recording with better resolution in conditions of fast and shallow breathing. Both piezoelectric and resistive methods are correct for creating sensors that monitor basic patients’ respiratory parameters. Their additional advantage is the simplicity and low cost of production which may be important in examining geriatric patients and neonates however piezoelectric is cheaper and less burdensome during the long-term recording of respiratory parameters","PeriodicalId":375541,"journal":{"name":"2021 28th International Conference on Mixed Design of Integrated Circuits and System","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 28th International Conference on Mixed Design of Integrated Circuits and System","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/MIXDES52406.2021.9497647","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The purpose of the work is to developed two sensors, based on piezoelectric and resistive elements, used to measure the respiratory signal from the thorax. As a result two innovative methods of monitoring respiratory parameters and cough incidents for patients with respiratory failure, caused by asthma or covid-19. The first sensor was made of the piezoelectric membrane, and the second uses conductive elastic rubber that changes its resistance when stretched. Both sensors were placed on the patient’s chest using a specially designed for this purpose belt.Simultaneous biomedical signals were recorded in laboratory conditions for various measurement methods, which showed chest movement during breathing in healthy people with the simulation of difficult measurement conditions, such as shallow and rapid breathing, slow deep breathing combined with apnea, and in the presence of motor disturbances. The obtained results for both measurement methods allow confirming a satisfactory immunity to movement disturbances and correct detection in extreme measurement conditions such as fast and shallow breathing and apnea while the piezoelectric method, enables recording with better resolution in conditions of fast and shallow breathing. Both piezoelectric and resistive methods are correct for creating sensors that monitor basic patients’ respiratory parameters. Their additional advantage is the simplicity and low cost of production which may be important in examining geriatric patients and neonates however piezoelectric is cheaper and less burdensome during the long-term recording of respiratory parameters
无源电子传感器记录生理信号获取呼吸参数方法在呼吸功能障碍患者中的有效性比较
这项工作的目的是开发两种基于压电和电阻元件的传感器,用于测量来自胸腔的呼吸信号。因此,对哮喘或covid-19引起的呼吸衰竭患者监测呼吸参数和咳嗽事件的两种创新方法。第一个传感器是由压电膜制成的,第二个使用导电弹性橡胶,当拉伸时它的电阻会改变。两个传感器都被放置在病人的胸部,使用专门设计的腰带。在实验室条件下,用各种测量方法同时记录生物医学信号,在模拟困难的测量条件下,如浅呼吸和快速呼吸,缓慢的深呼吸合并呼吸暂停,以及存在运动障碍的情况下,显示健康人呼吸时的胸部运动。两种测量方法获得的结果都可以在极端测量条件下(如快速浅呼吸和呼吸暂停)确认令人满意的运动干扰免疫和正确检测,而压电方法可以在快速浅呼吸条件下以更好的分辨率进行记录。压电法和电阻法都适用于制造监测病人基本呼吸参数的传感器。他们的额外优势是简单和低成本的生产,这可能是重要的,在检查老年患者和新生儿,但压电是更便宜,更少的负担,在长期记录呼吸参数
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信