A study of partial discharges in air with an ultra-wideband signal detector

A. Levy, O. Filho, E. Forster
{"title":"A study of partial discharges in air with an ultra-wideband signal detector","authors":"A. Levy, O. Filho, E. Forster","doi":"10.1109/ICPADM.1994.414071","DOIUrl":null,"url":null,"abstract":"Partial discharges in air have been the subject of many studies. Here, a study of individual partial discharges taking place in the nanosecond range has been performed to gain more definite information on their temporal characteristics. The total charge of such a single pulse was compared with the results obtained with a commercial partial discharge measuring system. A significant difference in the total charge measured by these two systems has been found. The significance of these findings is discussed in detail. Reference is also made to the pulsating characteristics observed for the individual current signals.<<ETX>>","PeriodicalId":331058,"journal":{"name":"Proceedings of 1994 4th International Conference on Properties and Applications of Dielectric Materials (ICPADM)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1994 4th International Conference on Properties and Applications of Dielectric Materials (ICPADM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPADM.1994.414071","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Partial discharges in air have been the subject of many studies. Here, a study of individual partial discharges taking place in the nanosecond range has been performed to gain more definite information on their temporal characteristics. The total charge of such a single pulse was compared with the results obtained with a commercial partial discharge measuring system. A significant difference in the total charge measured by these two systems has been found. The significance of these findings is discussed in detail. Reference is also made to the pulsating characteristics observed for the individual current signals.<>
用超宽带信号探测器研究空气中的局部放电
空气中的局部放电一直是许多研究的主题。在这里,对发生在纳秒范围内的单个部分放电进行了研究,以获得关于其时间特征的更明确的信息。将这种单脉冲的总电荷与商用局部放电测量系统获得的结果进行了比较。用这两种体系测得的总电荷有显著差异。详细讨论了这些发现的意义。还参考了观察到的单个电流信号的脉动特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信