Ultrahigh-resolution small-animal imaging using a silicon detector

T. Peterson, Donald W. Wilson, H. Barrett
{"title":"Ultrahigh-resolution small-animal imaging using a silicon detector","authors":"T. Peterson, Donald W. Wilson, H. Barrett","doi":"10.1109/NSSMIC.2003.1352269","DOIUrl":null,"url":null,"abstract":"We have developed a prototype ultrahigh-resolution small-animal imaging system that utilizes a silicon detector with a multiple-pinhole aperture. This system is suitable for imaging low-energy photons such as those from I-125 decay (27.2-35.5 keV) or the X-rays from I-123 decay (27.2-31.8 keV). The silicon detector is a double-sided strip detector of 300-micrometer thickness and 50-micrometer strip pitch, with 560 strips on one side and 1260 strips on the other. The readout utilizes VaTaGP2.2 ASICs from IDEAS ASA, Norway. When the detector is coupled with a multiple-pinhole aperture and operated in a synthetic-collimator configuration it should be possible to do tomographic image reconstructions without rotation of either the object or imager.","PeriodicalId":186175,"journal":{"name":"2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515)","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2003.1352269","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

We have developed a prototype ultrahigh-resolution small-animal imaging system that utilizes a silicon detector with a multiple-pinhole aperture. This system is suitable for imaging low-energy photons such as those from I-125 decay (27.2-35.5 keV) or the X-rays from I-123 decay (27.2-31.8 keV). The silicon detector is a double-sided strip detector of 300-micrometer thickness and 50-micrometer strip pitch, with 560 strips on one side and 1260 strips on the other. The readout utilizes VaTaGP2.2 ASICs from IDEAS ASA, Norway. When the detector is coupled with a multiple-pinhole aperture and operated in a synthetic-collimator configuration it should be possible to do tomographic image reconstructions without rotation of either the object or imager.
使用硅探测器的超高分辨率小动物成像
我们已经开发了一种原型的超高分辨率小动物成像系统,它利用了一个带有多针孔孔径的硅探测器。该系统适用于成像低能量光子,如来自I-125衰变(27.2-35.5 keV)或来自I-123衰变(27.2-31.8 keV)的x射线。硅探测器是厚度为300微米,带间距为50微米的双面带探测器,一面560条,另一面1260条。读出采用挪威IDEAS ASA的VaTaGP2.2 asic。当检测器与一个多针孔孔径相耦合并在一个合成准直器配置中操作时,它应该可以在不旋转物体或成像仪的情况下进行层析图像重建。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信