Modeling three-phase grid-connected inverter system using complex vector in synchronous dq reference frame and analysis on the influence of tuning parameters of synchronous frame PI controller

W. Choi, Casey T. Morris, B. Sarlioglu
{"title":"Modeling three-phase grid-connected inverter system using complex vector in synchronous dq reference frame and analysis on the influence of tuning parameters of synchronous frame PI controller","authors":"W. Choi, Casey T. Morris, B. Sarlioglu","doi":"10.1109/PECI.2016.7459235","DOIUrl":null,"url":null,"abstract":"This paper presents a mathematical modeling of three-phase grid-connected inverter system including output LCL filter and closed loop control using complex vector notation. The control scheme used is synchronous frame PI control on complex space vector of grid current in synchronous dq reference frame. Effect of controller's tuning parameters is investigated using complex vector root locus and complex vector frequency response function of closed loop system according to different tuning parameters. Control scheme and three-phase grid-connected inverter are simulated using MATLAB Simulink and SimPowerSystems™.","PeriodicalId":359438,"journal":{"name":"2016 IEEE Power and Energy Conference at Illinois (PECI)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Power and Energy Conference at Illinois (PECI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECI.2016.7459235","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

This paper presents a mathematical modeling of three-phase grid-connected inverter system including output LCL filter and closed loop control using complex vector notation. The control scheme used is synchronous frame PI control on complex space vector of grid current in synchronous dq reference frame. Effect of controller's tuning parameters is investigated using complex vector root locus and complex vector frequency response function of closed loop system according to different tuning parameters. Control scheme and three-phase grid-connected inverter are simulated using MATLAB Simulink and SimPowerSystems™.
在同步dq参照系下用复矢量建模三相并网逆变器系统,分析了同步参照系PI控制器整定参数的影响
本文用复向量法建立了包含输出LCL滤波器和闭环控制的三相并网逆变器系统的数学模型。所采用的控制方案是在同步dq参考系中对网格电流复空间矢量进行同步帧PI控制。根据不同的整定参数,利用闭环系统的复向量根轨迹和复向量频响函数研究了控制器整定参数的影响。利用MATLAB Simulink和SimPowerSystems™对控制方案和三相并网逆变器进行了仿真。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信