Direct voltage control of stand-alone DFIG in wind energy applications

B. Touaiti, H. Ben Azza, M. Jemli
{"title":"Direct voltage control of stand-alone DFIG in wind energy applications","authors":"B. Touaiti, H. Ben Azza, M. Jemli","doi":"10.1109/STA.2015.7505152","DOIUrl":null,"url":null,"abstract":"A power generation system has been formulated based on a doubly fed induction generator (DFIG) supplying isolated loads. The stator is connected to the isolated load. Only one bidirectional converter with a battery is employed on the rotor side. The direct voltage control (DVC) is applied to control the DFIG system. To regulate the voltage and frequency load, the error of the measured rotor current and reference value feed the hysteresis regulator, the output of which are the control pulses. The reference rotor currents are obtained by the DVC technique. Simulation results for a 3.7 kW prototype DFIG are presented in this paper.","PeriodicalId":128530,"journal":{"name":"2015 16th International Conference on Sciences and Techniques of Automatic Control and Computer Engineering (STA)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 16th International Conference on Sciences and Techniques of Automatic Control and Computer Engineering (STA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/STA.2015.7505152","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A power generation system has been formulated based on a doubly fed induction generator (DFIG) supplying isolated loads. The stator is connected to the isolated load. Only one bidirectional converter with a battery is employed on the rotor side. The direct voltage control (DVC) is applied to control the DFIG system. To regulate the voltage and frequency load, the error of the measured rotor current and reference value feed the hysteresis regulator, the output of which are the control pulses. The reference rotor currents are obtained by the DVC technique. Simulation results for a 3.7 kW prototype DFIG are presented in this paper.
单机DFIG在风能应用中的直接电压控制
提出了一种基于双馈感应发电机(DFIG)提供隔离负载的发电系统。定子连接到隔离负载上。只有一个双向转换器与电池是采用在转子侧。采用直接电压控制(DVC)对DFIG系统进行控制。为了调节电压和频率负载,测量转子电流和参考值的误差馈送迟滞调节器,其输出为控制脉冲。采用DVC技术获得转子参考电流。本文给出了一台3.7 kW样机的仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信