Development of Human Body Impedance Equivalent Circuit for Contact Current Measurement

Y. Kamimura, Soma Inagaki, K. Wake
{"title":"Development of Human Body Impedance Equivalent Circuit for Contact Current Measurement","authors":"Y. Kamimura, Soma Inagaki, K. Wake","doi":"10.1109/EMCEUROPE.2018.8485043","DOIUrl":null,"url":null,"abstract":"This study develops of a human body impedance equivalent circuit for contact current measurements. Experiments are conducted to measure the human body impedance of 19 adult men in the frequency range of 40 Hz to 10 MHz. The 10th and 50th percentile values are obtained. A circuit with optimal component values is built and its frequency characteristics are compared to those of measured values. Although resonance appeared at frequencies of > 15 MHz, the results confirm that the frequency characteristics of the proposed equivalent circuit match those of the human body.","PeriodicalId":376960,"journal":{"name":"2018 International Symposium on Electromagnetic Compatibility (EMC EUROPE)","volume":"05 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Symposium on Electromagnetic Compatibility (EMC EUROPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCEUROPE.2018.8485043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This study develops of a human body impedance equivalent circuit for contact current measurements. Experiments are conducted to measure the human body impedance of 19 adult men in the frequency range of 40 Hz to 10 MHz. The 10th and 50th percentile values are obtained. A circuit with optimal component values is built and its frequency characteristics are compared to those of measured values. Although resonance appeared at frequencies of > 15 MHz, the results confirm that the frequency characteristics of the proposed equivalent circuit match those of the human body.
接触电流测量人体阻抗等效电路的研制
本研究开发了一种人体阻抗等效电路,用于接触电流的测量。实验测量了19名成年男性在40 Hz ~ 10 MHz频率范围内的人体阻抗。得到第10和第50个百分位值。构建了具有最优分量值的电路,并将其频率特性与测量值进行了比较。虽然共振出现在> 15 MHz的频率,但结果证实了所提出的等效电路的频率特性与人体的频率特性相匹配。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信