Ventricular tachycardia in a parallel processing environment

J. Hsieh, W. Craelius
{"title":"Ventricular tachycardia in a parallel processing environment","authors":"J. Hsieh, W. Craelius","doi":"10.1109/ITAB.1998.674674","DOIUrl":null,"url":null,"abstract":"A one dimensional ring of cardiac tissue was modeled on parallel processors in order to investigate double wave reentry (DWR). The ring contained 1600 Beeler-Reuter cells, coupled by resistive gaps. The conditions required for DWR were studied using S1-S4 programmed stimulation. The results indicated the following: (1) A vulnerable window for DWR can be opened by S3, after wave collision is induced in the ring. Located between the points of collision and stimulation, the window is open for several milliseconds following S3. (2) Acceleration of tachycardia beyond DWR can be accomplished by adding a third reentrant wave in the same circuit, with the S3-S4 pacing protocol and sufficient substrate values. The number of reentrant waves and the degree of acceleration are limited only by the ratio of action potential duration to excitable gap.","PeriodicalId":126564,"journal":{"name":"Proceedings. 1998 IEEE International Conference on Information Technology Applications in Biomedicine, ITAB '98 (Cat. No.98EX188)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. 1998 IEEE International Conference on Information Technology Applications in Biomedicine, ITAB '98 (Cat. No.98EX188)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITAB.1998.674674","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A one dimensional ring of cardiac tissue was modeled on parallel processors in order to investigate double wave reentry (DWR). The ring contained 1600 Beeler-Reuter cells, coupled by resistive gaps. The conditions required for DWR were studied using S1-S4 programmed stimulation. The results indicated the following: (1) A vulnerable window for DWR can be opened by S3, after wave collision is induced in the ring. Located between the points of collision and stimulation, the window is open for several milliseconds following S3. (2) Acceleration of tachycardia beyond DWR can be accomplished by adding a third reentrant wave in the same circuit, with the S3-S4 pacing protocol and sufficient substrate values. The number of reentrant waves and the degree of acceleration are limited only by the ratio of action potential duration to excitable gap.
平行处理环境下的室性心动过速
为了研究心脏组织的双波再入(DWR)问题,在并行处理器上建立了一维心脏组织环的模型。该环包含1600个比勒-罗伊特细胞,由电阻隙连接。采用S1-S4程控增产技术研究了DWR所需条件。结果表明:(1)在环内诱导波碰撞后,S3可以打开DWR的脆弱窗口。该窗口位于碰撞点和刺激点之间,在S3之后打开几毫秒。(2)使用S3-S4起搏协议和足够的衬底值,可以通过在同一电路中添加第三个重入波来实现超过DWR的心动过速加速。重入波数和加速程度仅受动作电位持续时间与可激发间隙之比的限制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信