Comparison of efficiency of Double Conversion UPS with LC, LCL and LCL with damping resistor filters

Robinson Kong, Lee Kar Kuan, Mohd. Zaki Daud
{"title":"Comparison of efficiency of Double Conversion UPS with LC, LCL and LCL with damping resistor filters","authors":"Robinson Kong, Lee Kar Kuan, Mohd. Zaki Daud","doi":"10.1109/CENCON51869.2021.9627288","DOIUrl":null,"url":null,"abstract":"Technology advancement is currently rising at a rapid rate. This increases the demands for digital electronics industry in Malaysia. However, there is one issue when it comes to electronics, it is susceptible to power disturbance. Power disturbance can be categorized into six types which are transients, interruptions, undervoltage, overvoltage, waveform distortion and voltage fluctuations. In this study, an uninterruptible power supply (UPS) using double-conversion technique is presented due to its ability to provide adequate power conditioning and backup power in power disturbance situation. The simulation and designing of the converters such as rectifier, boost converter and inverter are presented using the MATLAB/Simulink. The simulation results showed that the UPS system was able to provide a continuous power supply with acceptable THD levels.","PeriodicalId":101715,"journal":{"name":"2021 IEEE Conference on Energy Conversion (CENCON)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE Conference on Energy Conversion (CENCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CENCON51869.2021.9627288","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Technology advancement is currently rising at a rapid rate. This increases the demands for digital electronics industry in Malaysia. However, there is one issue when it comes to electronics, it is susceptible to power disturbance. Power disturbance can be categorized into six types which are transients, interruptions, undervoltage, overvoltage, waveform distortion and voltage fluctuations. In this study, an uninterruptible power supply (UPS) using double-conversion technique is presented due to its ability to provide adequate power conditioning and backup power in power disturbance situation. The simulation and designing of the converters such as rectifier, boost converter and inverter are presented using the MATLAB/Simulink. The simulation results showed that the UPS system was able to provide a continuous power supply with acceptable THD levels.
采用LC、LCL和带阻尼电阻滤波器的LCL双转换UPS的效率比较
技术进步目前正以快速的速度上升。这增加了马来西亚对数字电子工业的需求。然而,当涉及到电子产品时,有一个问题,它容易受到电源干扰。电力干扰可分为六种类型,即瞬态、中断、欠压、过压、波形失真和电压波动。本研究提出一种采用双转换技术的不间断电源(UPS),可在电力干扰情况下提供足够的电力调节和备用电源。利用MATLAB/Simulink对整流、升压、逆变等变换器进行了仿真与设计。仿真结果表明,该UPS系统能够在可接受的THD水平下提供连续供电。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信