{"title":"EXPERIENCE IN USING ULTRA HIGH \nPERFORMANCE FIBER REINFORCED \nCONCRETE ELEMENTS","authors":"Maxim Marchenko, I. Chilin, N. Selyutin","doi":"10.37538/2224-9494-2021-3(30)-41-50","DOIUrl":null,"url":null,"abstract":"The article presents examples of the use of \nultra-high performance fiber reinforced concrete \nfor load-bearing structures in Russia. \nUsing this material with limits of compressive \nstrength 150 MPa, flexural tensile strength \n21 MPa, tensile strength 8.5 MPa, external \npost-tensioned structures of bridges and tanks \nare made instead of common solution with the \nsteel anchors. \nFull-scale tests of anchors were carried out, \nwhich did not reveal signs of deformations and \ndestruction of elements during the tension of \nstrands, at the level of design and ultimate \nloads - before strands rupture. \nIt was concluded that it is advisable to replace \nsteel anchors with anchors from the \nmaterial, which, with high strength characteristics, \nhas ultra-low permeability and high \nfrost resistance corresponding to the F21000 class. The estimated economic effect of such a replacement is determined by the reduced \ncost of these elements of structures made \nof ultra-high performance fiber reinforced \nconcrete in comparison with steel.","PeriodicalId":332973,"journal":{"name":"Bulletin of Science and Research Center “Stroitelstvo”","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of Science and Research Center “Stroitelstvo”","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37538/2224-9494-2021-3(30)-41-50","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The article presents examples of the use of ultra-high performance fiber reinforced concrete for load-bearing structures in Russia. Using this material with limits of compressive strength 150 MPa, flexural tensile strength 21 MPa, tensile strength 8.5 MPa, external post-tensioned structures of bridges and tanks are made instead of common solution with the steel anchors. Full-scale tests of anchors were carried out, which did not reveal signs of deformations and destruction of elements during the tension of strands, at the level of design and ultimate loads - before strands rupture. It was concluded that it is advisable to replace steel anchors with anchors from the material, which, with high strength characteristics, has ultra-low permeability and high frost resistance corresponding to the F21000 class. The estimated economic effect of such a replacement is determined by the reduced cost of these elements of structures made of ultra-high performance fiber reinforced concrete in comparison with steel.
有使用超高性能纤维增强混凝土构件的经验
文章介绍了俄罗斯在承重结构中使用超高性能纤维增强混凝土的实例。该材料极限抗压强度为150 MPa,抗折抗拉强度为21 MPa,抗拉强度为8.5 MPa,可用于桥梁和储罐的外部后张结构,代替常用的钢锚解决方案。对锚杆进行了全面测试,在锚索断裂之前,在设计和极限载荷水平上,在锚索拉伸期间,没有发现变形和元件破坏的迹象。结果表明,采用与F21000级相对应的超低渗、高抗冻性能的高强度材料的锚杆代替钢锚是可取的。这种替代的估计经济效果取决于与钢相比,由超高性能纤维增强混凝土制成的这些结构元素的成本降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信