PET attenuation correction using mean attenuation coefficients: a simulation study

M. Madsen
{"title":"PET attenuation correction using mean attenuation coefficients: a simulation study","authors":"M. Madsen","doi":"10.1109/NSSMIC.1998.773895","DOIUrl":null,"url":null,"abstract":"It is desirable to use mean population attenuation coefficients to reduce the statistical fluctuations in measured attenuation maps. In addition, the use of mean attenuation coefficients is also expected to facilitate algorithmic approaches to attenuation correction. Because of the large variation in lung attenuation coefficients both within and among individuals, there is concern about the errors using mean attenuation might create. To test the magnitude of this problem, myocardial metabolic studies were simulated. Attenuated projections were generated from 20 realistic emission and transmission distributions spanning the heart volume. The projections were corrected with both the actual attenuation map and with a mean attenuation map. Quantitative comparisons of the reconstructed images demonstrate no significant differences in the myocardial distributions. However, errors in the lung field exceeded 300% in some regions.","PeriodicalId":129202,"journal":{"name":"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1998.773895","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

It is desirable to use mean population attenuation coefficients to reduce the statistical fluctuations in measured attenuation maps. In addition, the use of mean attenuation coefficients is also expected to facilitate algorithmic approaches to attenuation correction. Because of the large variation in lung attenuation coefficients both within and among individuals, there is concern about the errors using mean attenuation might create. To test the magnitude of this problem, myocardial metabolic studies were simulated. Attenuated projections were generated from 20 realistic emission and transmission distributions spanning the heart volume. The projections were corrected with both the actual attenuation map and with a mean attenuation map. Quantitative comparisons of the reconstructed images demonstrate no significant differences in the myocardial distributions. However, errors in the lung field exceeded 300% in some regions.
利用平均衰减系数校正PET衰减:模拟研究
希望使用平均总体衰减系数来减少测量衰减图中的统计波动。此外,平均衰减系数的使用也有望促进衰减校正的算法方法。由于个体内部和个体之间肺衰减系数的差异很大,因此人们担心使用平均衰减可能会产生误差。为了测试这个问题的严重程度,我们模拟了心肌代谢研究。衰减投影由20个真实的辐射和传输分布产生,跨越心脏体积。投影用实际衰减图和平均衰减图进行校正。重建图像的定量比较显示心肌分布无显著差异。然而,在某些地区,肺场的错误率超过300%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信