Shape Adaptable Medical Multimedia Processing

Ali J. Abboud
{"title":"Shape Adaptable Medical Multimedia Processing","authors":"Ali J. Abboud","doi":"10.2174/1874129001913010001","DOIUrl":null,"url":null,"abstract":"Electronic medical healthcare systems are becoming the backbone of health organizations over the world. The huge amounts of medical multimedia produced by these systems especially images and videos are transmitted by the computer networks that connect these systems. The variability in the shape and texture of transferred medical multimedia data needs adaptable procedures to process these data efficiently. In other words, these procedures must adjust automatically based on the shape of region of interests in the medical multimedia images to cope with fast changes in the healthcare environments. In this paper, we have proposed shape adaptable watermarking approaches for medical multimedia processing systems. The medical images generated by X-rays, MRI and CT modalities are used in our experiments to test proposed approaches. In addition, these approaches were tested under different kinds of signal processing and geometric attacks. The comparative comparison of our proposed approaches with state-of-art approaches proved the superiority and capability of our approaches to adjust the number of selected subands of medical cover image to embed and extract the hospital watermark logos.The development of an adjustable approach to process medical multimedia signals for healthcare system. The aim of this research is to select adaptably the number of subands of cover image to hide the information of hospital logo watermark inside them such that embedded watermarks can resist different kinds of attacks.The proposed adjustable approach consists of suband selection method, criterion, embedding and extraction procedures, DWT transform, attacks, evaluation metrics,etc.It provides robust and adjustable method to embed and extract watermark logo at different resolution levels of cover medical image and uses with images of different sizes and modalities.","PeriodicalId":370221,"journal":{"name":"The Open Electrical & Electronic Engineering Journal","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Open Electrical & Electronic Engineering Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1874129001913010001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Electronic medical healthcare systems are becoming the backbone of health organizations over the world. The huge amounts of medical multimedia produced by these systems especially images and videos are transmitted by the computer networks that connect these systems. The variability in the shape and texture of transferred medical multimedia data needs adaptable procedures to process these data efficiently. In other words, these procedures must adjust automatically based on the shape of region of interests in the medical multimedia images to cope with fast changes in the healthcare environments. In this paper, we have proposed shape adaptable watermarking approaches for medical multimedia processing systems. The medical images generated by X-rays, MRI and CT modalities are used in our experiments to test proposed approaches. In addition, these approaches were tested under different kinds of signal processing and geometric attacks. The comparative comparison of our proposed approaches with state-of-art approaches proved the superiority and capability of our approaches to adjust the number of selected subands of medical cover image to embed and extract the hospital watermark logos.The development of an adjustable approach to process medical multimedia signals for healthcare system. The aim of this research is to select adaptably the number of subands of cover image to hide the information of hospital logo watermark inside them such that embedded watermarks can resist different kinds of attacks.The proposed adjustable approach consists of suband selection method, criterion, embedding and extraction procedures, DWT transform, attacks, evaluation metrics,etc.It provides robust and adjustable method to embed and extract watermark logo at different resolution levels of cover medical image and uses with images of different sizes and modalities.
形状适应性医学多媒体处理
电子医疗保健系统正在成为世界各地卫生组织的支柱。这些系统产生的大量医学多媒体,特别是图像和视频,通过连接这些系统的计算机网络传输。传输的医学多媒体数据在形状和纹理上的可变性需要适应的程序来有效地处理这些数据。换句话说,这些程序必须根据医学多媒体图像中感兴趣区域的形状自动调整,以应对医疗环境的快速变化。本文提出了一种用于医学多媒体处理系统的形状自适应水印方法。我们在实验中使用x射线、核磁共振成像和CT模式产生的医学图像来测试提出的方法。此外,还在不同的信号处理和几何攻击下对这些方法进行了测试。将本文提出的方法与现有方法进行比较,证明了本文提出的方法在调整医学封面图像所选子标数以嵌入和提取医院水印标识方面的优越性和能力。一种可调节的医疗多媒体信号处理方法的发展。本研究的目的是自适应地选择封面图像的子图像数量,将医院标志水印信息隐藏在子图像中,使嵌入的水印能够抵抗不同类型的攻击。该方法包括子区选择方法、准则、嵌入和提取步骤、DWT变换、攻击、评价指标等。它提供了鲁棒性和可调的方法来嵌入和提取不同分辨率水平的覆盖医学图像水印标志,并用于不同尺寸和模式的图像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信