A New Modulation Technique for A Three-Cell Single-Phase CHB Inverter with Un-Equal DC-Link Voltage for Improving Output Voltage Quality

I. Citarsa, I. N. Satiawan, Supriono
{"title":"A New Modulation Technique for A Three-Cell Single-Phase CHB Inverter with Un-Equal DC-Link Voltage for Improving Output Voltage Quality","authors":"I. Citarsa, I. N. Satiawan, Supriono","doi":"10.1109/AEMT.2018.8572358","DOIUrl":null,"url":null,"abstract":"This paper investigates a new modulation technique for a three-cell single-phase CHB (Cascaded H-Bridge) inverter with un-equal DC link voltage. The proposed PWM technique is verified using Matlab/Simulink. The applied DC-link voltages of inverter are 6 V, 12 V and 24 V respectively (DC-link voltage ratio of 1: 2: 4). The result is compared with the CHB inverter with equal DC-link voltage (using DC-link voltage of 12 Volt). The simulation results show that the output voltage using DC-link voltage ratio of 1: 2: 4 produces 15 levels DC voltage, while equal DC-link can only generate a 7 voltage levels. As the number of level in the output voltage increases, the quality of the voltage improves significantly. This is indicated by the reduction of THD percentage from 13.22% to 5.265% that can be seen from the harmonics spectrum of the three-cell CHB inverter using conventional and new PWM. The harmonics spectrum also shown that the output voltage of the three-cell CHB inverter using new PWM is almost free from harmonics, while using the conventional PWM, the 3rd, 5th and 7th harmonics and some higher harmonics are still appeared. Another indicator is carried out by comparing the percentage of low order harmonics content up to the 19th harmonic (950 Hz) of the output voltage. It is noted that there is a significant reduction of the low order harmonics from 3.25% to 0.518% achieved using the new PWM method. To sum up, the new modulation technique enables the inverter to produce better output voltage quality.","PeriodicalId":371263,"journal":{"name":"2018 2nd International Conference on Applied Electromagnetic Technology (AEMT)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-04-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 2nd International Conference on Applied Electromagnetic Technology (AEMT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AEMT.2018.8572358","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper investigates a new modulation technique for a three-cell single-phase CHB (Cascaded H-Bridge) inverter with un-equal DC link voltage. The proposed PWM technique is verified using Matlab/Simulink. The applied DC-link voltages of inverter are 6 V, 12 V and 24 V respectively (DC-link voltage ratio of 1: 2: 4). The result is compared with the CHB inverter with equal DC-link voltage (using DC-link voltage of 12 Volt). The simulation results show that the output voltage using DC-link voltage ratio of 1: 2: 4 produces 15 levels DC voltage, while equal DC-link can only generate a 7 voltage levels. As the number of level in the output voltage increases, the quality of the voltage improves significantly. This is indicated by the reduction of THD percentage from 13.22% to 5.265% that can be seen from the harmonics spectrum of the three-cell CHB inverter using conventional and new PWM. The harmonics spectrum also shown that the output voltage of the three-cell CHB inverter using new PWM is almost free from harmonics, while using the conventional PWM, the 3rd, 5th and 7th harmonics and some higher harmonics are still appeared. Another indicator is carried out by comparing the percentage of low order harmonics content up to the 19th harmonic (950 Hz) of the output voltage. It is noted that there is a significant reduction of the low order harmonics from 3.25% to 0.518% achieved using the new PWM method. To sum up, the new modulation technique enables the inverter to produce better output voltage quality.
一种提高输出电压质量的直流电压不等的三相单相CHB逆变器调制新技术
本文研究了直流链路电压不相等的三单元单相级联h桥逆变器的调制技术。利用Matlab/Simulink对所提出的PWM技术进行了验证。逆变器的直流电压分别为6 V、12 V和24 V(直流电压比为1:2:4),并与同等直流电压(直流电压为12伏)的CHB逆变器进行比较。仿真结果表明,采用直流链路电压比为1:2:4的输出电压可产生15个电平的直流电压,而相同的直流链路只能产生7个电平的直流电压。随着输出电压电平数的增加,电压质量明显提高。这可以从使用传统PWM和新型PWM的三单元CHB逆变器的谐波谱中看出,THD百分比从13.22%降低到5.265%。谐波谱还表明,采用新型PWM的三单元CHB逆变器输出电压几乎不存在谐波,而采用传统PWM的三单元CHB逆变器输出电压仍然存在3、5、7次谐波和部分高次谐波。另一个指标是通过比较输出电压的19次谐波(950 Hz)的低次谐波含量的百分比来进行的。值得注意的是,使用新的PWM方法可以将低次谐波从3.25%显著降低到0.518%。综上所述,新的调制技术可以使逆变器产生更好的输出电压质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信