Design of Probe Intervals to Improve Accuracy of CoMPACT Monitor

Kohei Watabe, Y. Honma, M. Aida
{"title":"Design of Probe Intervals to Improve Accuracy of CoMPACT Monitor","authors":"Kohei Watabe, Y. Honma, M. Aida","doi":"10.1109/INCOS.2009.42","DOIUrl":null,"url":null,"abstract":"We have proposed CoMPACT monitor that achieves scalable measurement of one-way delay distribution for each flow. CoMPACT monitor is technique that transforms one-way delay data obtained by active measurement by using passively monitored traffic data of the target flow. In a recent study, it was reported that by using an inter-probe time that has a Gamma distribution can improve the accuracy of simple active measurement. The improvement is in terms of the ensemble mean of stationary stochastic process. In this paper, to improve accuracy of CoMPACT monitor, we apply Gamma-probing as an active measurement of CoMPACT monitor. The significant issue in this application is in the difference between objects to measure; CoMPACT monitor estimates not the ensemble mean but the time average of sample path. We investigate the characteristics of CoMPACT monitor and Gamma-probing, and verify the accuracy improvement of CoMPACT monitor through simulations.","PeriodicalId":145328,"journal":{"name":"2009 International Conference on Intelligent Networking and Collaborative Systems","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Conference on Intelligent Networking and Collaborative Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INCOS.2009.42","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We have proposed CoMPACT monitor that achieves scalable measurement of one-way delay distribution for each flow. CoMPACT monitor is technique that transforms one-way delay data obtained by active measurement by using passively monitored traffic data of the target flow. In a recent study, it was reported that by using an inter-probe time that has a Gamma distribution can improve the accuracy of simple active measurement. The improvement is in terms of the ensemble mean of stationary stochastic process. In this paper, to improve accuracy of CoMPACT monitor, we apply Gamma-probing as an active measurement of CoMPACT monitor. The significant issue in this application is in the difference between objects to measure; CoMPACT monitor estimates not the ensemble mean but the time average of sample path. We investigate the characteristics of CoMPACT monitor and Gamma-probing, and verify the accuracy improvement of CoMPACT monitor through simulations.
提高紧凑型监测仪精度的探头间隔设计
我们提出了紧凑型监视器,实现了对每个流的单向延迟分布的可扩展测量。紧凑型监控是一种利用目标流的被动监控交通数据,将主动测量得到的单向时延数据进行转换的技术。在最近的一项研究中,报道了通过使用具有Gamma分布的探针间时间可以提高简单主动测量的精度。改进是在平稳随机过程的集合均值方面。为了提高紧凑型监测仪的测量精度,本文将伽马探测作为紧凑型监测仪的主动测量方法。这个应用中的重要问题是要测量的对象之间的差异;紧凑型监测仪估计的不是集合均值,而是样本路径的时间平均值。研究了紧凑型监测仪和伽马探测的特点,并通过仿真验证了紧凑型监测仪精度的提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信