Field studies on thermal comfort of air-conditioned and non air-conditioned buildings in Malaysia

I. Hussein, M. A. A. Rahman, T. María
{"title":"Field studies on thermal comfort of air-conditioned and non air-conditioned buildings in Malaysia","authors":"I. Hussein, M. A. A. Rahman, T. María","doi":"10.1109/ICEENVIRON.2009.5398622","DOIUrl":null,"url":null,"abstract":"Field studies on the environmental conditions and occupant comfort were carried out in air-conditioned buildings and non air-conditioned buildings in Malaysia. The study on the air-conditioned buildings was carried out in UNITEN and for the non air-conditioned buildings in two schools, which is a primary and secondary school, and in a public waiting area in a health clinic in Johor Bahru, located in the southern region of Malaysia. The non air-conditioned buildings were mechanically ventilated by fans. The studies were made in different days from morning until noon as to get variation of temperatures, collecting a full set of objective physical measurements and subjective assessments through questionnaires. The measured environmental parameters were air temperature, relative humidity and air velocity. The subjective responses concern the judgment of the respondents about the thermal environment at the moment of measurements. The results obtained showed that majority of the respondents found that their indoor thermal conditions acceptable even though most of the thermal sensation votes (TSV) exceeded those specified by ASHRAE Standard 55 and the environmental assessments exceeded the standard. The neutral temperature and comfort range were obtained through linear regression analysis of TSV and in the Fanger's PMV model. From the subjective assessment, it was found that the occupants can accept the thermal range beyond the ASHRAE comfort zone. The neutral temperature of 24.4°C and 28.4°C for air-conditioned and non air-conditioned buildings respectively, were obtained by regression analysis of TSV on operative temperature. The acceptable range of temperature obtained by regression analysis of TSV were 23.1°C to 25.6°C for air-conditioned buildings and 26.0°C to 30.7°C for non air-conditioned buildings.","PeriodicalId":211736,"journal":{"name":"2009 3rd International Conference on Energy and Environment (ICEE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"29","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 3rd International Conference on Energy and Environment (ICEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEENVIRON.2009.5398622","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 29

Abstract

Field studies on the environmental conditions and occupant comfort were carried out in air-conditioned buildings and non air-conditioned buildings in Malaysia. The study on the air-conditioned buildings was carried out in UNITEN and for the non air-conditioned buildings in two schools, which is a primary and secondary school, and in a public waiting area in a health clinic in Johor Bahru, located in the southern region of Malaysia. The non air-conditioned buildings were mechanically ventilated by fans. The studies were made in different days from morning until noon as to get variation of temperatures, collecting a full set of objective physical measurements and subjective assessments through questionnaires. The measured environmental parameters were air temperature, relative humidity and air velocity. The subjective responses concern the judgment of the respondents about the thermal environment at the moment of measurements. The results obtained showed that majority of the respondents found that their indoor thermal conditions acceptable even though most of the thermal sensation votes (TSV) exceeded those specified by ASHRAE Standard 55 and the environmental assessments exceeded the standard. The neutral temperature and comfort range were obtained through linear regression analysis of TSV and in the Fanger's PMV model. From the subjective assessment, it was found that the occupants can accept the thermal range beyond the ASHRAE comfort zone. The neutral temperature of 24.4°C and 28.4°C for air-conditioned and non air-conditioned buildings respectively, were obtained by regression analysis of TSV on operative temperature. The acceptable range of temperature obtained by regression analysis of TSV were 23.1°C to 25.6°C for air-conditioned buildings and 26.0°C to 30.7°C for non air-conditioned buildings.
马来西亚空调与非空调建筑热舒适性的实地研究
在马来西亚的空调建筑和非空调建筑中进行了环境条件和居住者舒适度的实地研究。对空调建筑的研究是在UNITEN进行的,对两所学校(一所小学和一所中学)的非空调建筑以及位于马来西亚南部地区新山的一家诊所的公共等候区进行的。没有空调的建筑物用风扇进行机械通风。研究在不同的日子里从早上到中午进行,以获得温度的变化,收集了一整套客观的物理测量和通过问卷的主观评估。测量的环境参数为空气温度、相对湿度和空气速度。主观反应涉及应答者在测量时对热环境的判断。结果表明,尽管大部分的热感觉投票(TSV)超过了ASHRAE标准55的规定,并且环境评价超出了标准,但大多数受访者认为他们的室内热条件是可以接受的。通过对TSV和Fanger的PMV模型进行线性回归分析,得出中性温度和舒适范围。从主观评价来看,居住者可以接受ASHRAE舒适区以外的热范围。通过对TSV对工作温度的回归分析,得到空调和非空调建筑的中性温度分别为24.4°C和28.4°C。通过TSV回归分析得到的可接受温度范围,空调建筑为23.1 ~ 25.6℃,非空调建筑为26.0 ~ 30.7℃。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信