{"title":"Analysis of power losses of the 150 kV transmission using Poynting vector","authors":"S. Manjang, Y. George, I. Kitta","doi":"10.1109/ICPERE.2012.6287221","DOIUrl":null,"url":null,"abstract":"If a conductor given voltage, then there will be electric field and magnetic field along the conductor, as a result of sinusoidal waves which change with time. Besides, it will cause the power loss along the conductor, especially for long lines and has a high voltage. The main purpose of this study was to determine power loss that occurs in the 150 kV overhead. One of effective method to calculate the power loss in the transmission line is the Poynting vector theorem is analyzed based on the amount of the electric field and magnetic field intensity generated. Based on the results of the analysis conducted in this study found that the magnitude of power loss at lines 150 kV with a routes SUTT Bakarul-Pinrang-Tuppu, Pinrang - Pare-pare, Pare-pare - barru-Pangkep, and Pangkep-Bosowa-Tello amounted to 5.4505 MW with a total transmission line length of 230.138 km.","PeriodicalId":303729,"journal":{"name":"2012 International Conference on Power Engineering and Renewable Energy (ICPERE)","volume":"54 33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Power Engineering and Renewable Energy (ICPERE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPERE.2012.6287221","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

If a conductor given voltage, then there will be electric field and magnetic field along the conductor, as a result of sinusoidal waves which change with time. Besides, it will cause the power loss along the conductor, especially for long lines and has a high voltage. The main purpose of this study was to determine power loss that occurs in the 150 kV overhead. One of effective method to calculate the power loss in the transmission line is the Poynting vector theorem is analyzed based on the amount of the electric field and magnetic field intensity generated. Based on the results of the analysis conducted in this study found that the magnitude of power loss at lines 150 kV with a routes SUTT Bakarul-Pinrang-Tuppu, Pinrang - Pare-pare, Pare-pare - barru-Pangkep, and Pangkep-Bosowa-Tello amounted to 5.4505 MW with a total transmission line length of 230.138 km.
用坡印亭矢量分析150kv输电系统的功率损耗
如果一个导体给定电压,那么沿着导体就会有电场和磁场,这是正弦波随时间变化的结果。此外,它会造成沿导体的功率损耗,特别是对于长线路和高压线路。本研究的主要目的是确定发生在150千伏架空的功率损失。根据产生的电场大小和磁场强度,分析了波印亭矢量定理是计算输电线路功率损耗的有效方法之一。根据本研究的分析结果,在SUTT Bakarul-Pinrang-Tuppu, Pinrang- Pare-pare, Pare-pare - barru-Pangkep和Pangkep-Bosowa-Tello线路上的150 kV线路的功率损耗幅度为5.4505 MW,总输电线路长度为230.138公里。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信