Comparison of Two Different Electro Polish Temperature on Cobalt Ion Release of Chromium Cobalt Alloy in Artificial Saliva with Atomic Absorption Spectrophotometry

Amir Adib, M. Mahabadi, Fatemeh Rashidi Meybodi, Sayed Mohammad Mehdi S Alehi Abari
{"title":"Comparison of Two Different Electro Polish Temperature on Cobalt Ion Release of Chromium Cobalt Alloy in Artificial Saliva with Atomic Absorption Spectrophotometry","authors":"Amir Adib, M. Mahabadi, Fatemeh Rashidi Meybodi, Sayed Mohammad Mehdi S Alehi Abari","doi":"10.18502/ijds.v18i3.11238","DOIUrl":null,"url":null,"abstract":"Introduction: Metals are widely used in direct and indirect restorative materials, both in prosthetics and orthodontics. The biocompatibility of these metals depends on their chemical nature, the number of ions released, and the period of contact of these metals. This study aims to compare two different electropolish temperatures on the release of cobalt ion from chromium-cobalt alloy. \nMaterials & Methods: In this experimental study, 24 wax patterns were cut in the form of a circle with a diameter of 15 mm and a thickness of 1 mm. Then, the samples were sprued and invested. Burn out and casting were used to cast the alloy. The samples were sandblasted and polished with aluminum oxide. They were randomly divided into two 12-number groups and electropolished at 45° and 55° C. Samples were placed in artificial saliva and sent to atomic absorption spectrophotometer for 15 and 30 days to read the cobalt. Data were then analyzed by Independent t-test and Paired t-test (p value = 0.05). \nResults: The average release of cobalt from chromium cobalt alloy on the 30th day was higher than the 15th day at both 45°C and 55°C. This difference was significant at 45°C (p value = 0.036) while not significant at 55°C (p value = 0.0754). Regarding the comparison of the ion release at 45° and 55°C, the difference was not significant on the 15th day (p value = 0.067) and 30th day (p value = 0.0754). \nConclusion: The amount of cobalt ions released from the cobalt-chromium alloy at 45°C is fewer than at 55°C over time. \n ","PeriodicalId":221865,"journal":{"name":"Journal of Isfahan Dental School","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Isfahan Dental School","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/ijds.v18i3.11238","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Metals are widely used in direct and indirect restorative materials, both in prosthetics and orthodontics. The biocompatibility of these metals depends on their chemical nature, the number of ions released, and the period of contact of these metals. This study aims to compare two different electropolish temperatures on the release of cobalt ion from chromium-cobalt alloy. Materials & Methods: In this experimental study, 24 wax patterns were cut in the form of a circle with a diameter of 15 mm and a thickness of 1 mm. Then, the samples were sprued and invested. Burn out and casting were used to cast the alloy. The samples were sandblasted and polished with aluminum oxide. They were randomly divided into two 12-number groups and electropolished at 45° and 55° C. Samples were placed in artificial saliva and sent to atomic absorption spectrophotometer for 15 and 30 days to read the cobalt. Data were then analyzed by Independent t-test and Paired t-test (p value = 0.05). Results: The average release of cobalt from chromium cobalt alloy on the 30th day was higher than the 15th day at both 45°C and 55°C. This difference was significant at 45°C (p value = 0.036) while not significant at 55°C (p value = 0.0754). Regarding the comparison of the ion release at 45° and 55°C, the difference was not significant on the 15th day (p value = 0.067) and 30th day (p value = 0.0754). Conclusion: The amount of cobalt ions released from the cobalt-chromium alloy at 45°C is fewer than at 55°C over time.  
原子吸收分光光度法比较两种不同电抛光温度对人工唾液中铬钴合金钴离子释放的影响
金属是广泛应用于义肢和正畸的直接和间接修复材料。这些金属的生物相容性取决于它们的化学性质、释放的离子数量以及与这些金属接触的时间。本研究旨在比较两种不同的电抛光温度对铬钴合金中钴离子释放的影响。材料与方法:在本实验研究中,将24个蜡模切割成直径为15mm,厚度为1mm的圆形。然后,对样品进行发芽和投资。合金的铸造采用烧尽法和铸造法。样品经喷砂和氧化铝抛光处理。将样品随机分为两组,分别在45°和55°c下进行电抛光。将样品置于人工唾液中,用原子吸收分光光度计测定15和30天的钴含量。采用独立t检验和配对t检验(p值= 0.05)对数据进行分析。结果:在45℃和55℃条件下,第30天铬钴合金中钴的平均释放量均高于第15天。这种差异在45°C时显著(p值= 0.036),而在55°C时不显著(p值= 0.0754)。45°和55°C时离子释放量比较,第15天(p值= 0.067)和第30天(p值= 0.0754)差异不显著。结论:随着时间的推移,45℃时钴铬合金中钴离子的释放量小于55℃时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信