Harmonic current emission of photovoltaic installations under system conditions

Juergen Schlabbach
{"title":"Harmonic current emission of photovoltaic installations under system conditions","authors":"Juergen Schlabbach","doi":"10.1109/EEM.2008.4579000","DOIUrl":null,"url":null,"abstract":"Harmonic currents of PV-inverters show a significant dependency on the harmonic voltage content of the AC-system voltage. Measurements of harmonic currents were carried out in LV-systems and under laboratory test conditions with adjustable harmonic content of the AV-voltage. Two PV-inverters, one with coupling transformer and one without transformer were tested. The results indicated that the emitted harmonic currents depend strongly on the harmonic voltages prevailing in the AC-voltage. PV-inverters without transformer show significant lower harmonic currents than inverters with coupling transformer. The standard test conditions as defined in international standards does not consider real system conditions with respect to the harmonic voltages in system voltage. The measured currents as documented in data sheets are therefore comparatively lower than under the condition of real system operation.","PeriodicalId":118618,"journal":{"name":"2008 5th International Conference on the European Electricity Market","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"26","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 5th International Conference on the European Electricity Market","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEM.2008.4579000","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

Abstract

Harmonic currents of PV-inverters show a significant dependency on the harmonic voltage content of the AC-system voltage. Measurements of harmonic currents were carried out in LV-systems and under laboratory test conditions with adjustable harmonic content of the AV-voltage. Two PV-inverters, one with coupling transformer and one without transformer were tested. The results indicated that the emitted harmonic currents depend strongly on the harmonic voltages prevailing in the AC-voltage. PV-inverters without transformer show significant lower harmonic currents than inverters with coupling transformer. The standard test conditions as defined in international standards does not consider real system conditions with respect to the harmonic voltages in system voltage. The measured currents as documented in data sheets are therefore comparatively lower than under the condition of real system operation.
系统条件下光伏装置的谐波电流发射
光伏逆变器的谐波电流与交流系统电压的谐波电压含量有很大的关系。谐波电流的测量在lv系统和实验室测试条件下进行,可调节av电压的谐波含量。测试了两个光伏逆变器,一个带耦合变压器,一个不带变压器。结果表明,所发射的谐波电流在很大程度上取决于交流电压中的谐波电压。不带变压器的逆变器谐波电流明显低于带耦合变压器的逆变器。国际标准中定义的标准测试条件没有考虑系统电压中谐波电压的实际系统条件。因此,数据表中记录的测量电流相对低于实际系统运行时的电流。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信