Performance Evaluation of Highrise Building Structure Based on Pushover Analysis with ATC-40 Method

Dermawan Zebua, K. *
{"title":"Performance Evaluation of Highrise Building Structure Based on Pushover Analysis with ATC-40 Method","authors":"Dermawan Zebua, K. *","doi":"10.32722/arcee.v3i02.4334","DOIUrl":null,"url":null,"abstract":"The concept of earthquake-resistant buildings is very meaningful to try on buildings located in certain earthquake areas, especially in Indonesia considering the situation which is located in a shock area with a fairly high intensity of events. The purpose of this research is to determine the seismic performance criteria of the planned structure using the SMRF (Special Moment Resisting Frame) structural system from the results of the displacement values ​​using the ATC-40 code, showing the yielding scheme (plastic joint distribution) that occurs from the calculation results of the software program, knowing the pattern of building collapse so that it can be known joint- joint that is damaged and damaged from the pushover analysis. From the results of the research, the building structure is able to provide nonlinear behavior which is indicated by the initial phase and the majority of the occurrence of plastic joints occurs in new beam elements and then column elements and has fulfilled the earthquake-resistant building concept, namely strong column - weak beam. The results of the structural performance evaluation according to the ATC-40 rule that the Performance Level of the SMRF building in the x and y directions is at a Performance Level of 0.011 in the Immediate Occupancy (IO) category where the building is safe during an earthquake, the risk of loss of life and structural failure is not too significant, the building does not experience significant damage, and can be reused and not disturbed by repair problems, where the strength and stiffness are approximately the same as the conditions before the earthquake.","PeriodicalId":378971,"journal":{"name":"Applied Research on Civil Engineering and Environment (ARCEE)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Research on Civil Engineering and Environment (ARCEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32722/arcee.v3i02.4334","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The concept of earthquake-resistant buildings is very meaningful to try on buildings located in certain earthquake areas, especially in Indonesia considering the situation which is located in a shock area with a fairly high intensity of events. The purpose of this research is to determine the seismic performance criteria of the planned structure using the SMRF (Special Moment Resisting Frame) structural system from the results of the displacement values ​​using the ATC-40 code, showing the yielding scheme (plastic joint distribution) that occurs from the calculation results of the software program, knowing the pattern of building collapse so that it can be known joint- joint that is damaged and damaged from the pushover analysis. From the results of the research, the building structure is able to provide nonlinear behavior which is indicated by the initial phase and the majority of the occurrence of plastic joints occurs in new beam elements and then column elements and has fulfilled the earthquake-resistant building concept, namely strong column - weak beam. The results of the structural performance evaluation according to the ATC-40 rule that the Performance Level of the SMRF building in the x and y directions is at a Performance Level of 0.011 in the Immediate Occupancy (IO) category where the building is safe during an earthquake, the risk of loss of life and structural failure is not too significant, the building does not experience significant damage, and can be reused and not disturbed by repair problems, where the strength and stiffness are approximately the same as the conditions before the earthquake.
基于ATC-40法推覆分析的高层建筑结构性能评价
抗震建筑的概念对于位于某些震区的建筑来说是非常有意义的,特别是考虑到印度尼西亚位于地震强度相当高的震区的情况。本研究的目的是根据ATC-40规范的位移值结果确定SMRF(特殊抗矩框架)结构体系的规划结构的抗震性能标准,显示从软件程序的计算结果产生的屈服方案(塑性节点分布),了解建筑物倒塌的模式,从而可以从推覆分析中知道接缝-损坏和损坏的接缝。研究结果表明,该结构在初始阶段表现出较强的非线性特性,塑性节点主要发生在新梁单元,然后是柱单元,实现了强柱弱梁的抗震结构概念。根据ATC-40规则的结构性能评估结果,SMRF建筑在x和y方向的性能水平在立即使用(IO)类别中的性能水平为0.011,其中建筑物在地震期间是安全的,生命损失和结构破坏的风险不是太大,建筑物没有遭受重大破坏,可以重复使用且不会受到维修问题的干扰。其中强度和刚度与地震前的条件大致相同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信