Time calibration and monitoring in the ATLAS Tile Calorimeter

S. Polacek
{"title":"Time calibration and monitoring in the ATLAS Tile Calorimeter","authors":"S. Polacek","doi":"10.22323/1.380.0106","DOIUrl":null,"url":null,"abstract":"The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the central region of the ATLAS experiment at the LHC. This sampling device uses steel plates as an absorber and scintillating tiles as the active medium. Its response is calibrated to the electromagnetic scale by means of several dedicated calibration systems. The accurate time calibration is important for the energy reconstruction, non-collision background removal as well as for specific physics analyses. The time calibration as performed with collision data is presented. Its monitoring with laser system and collision data is discussed as well and the corrections for various identified problems. Finally, the time resolution as measured with jets in Run 2 is presented.","PeriodicalId":135659,"journal":{"name":"Proceedings of Particles and Nuclei International Conference 2021 — PoS(PANIC2021)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Particles and Nuclei International Conference 2021 — PoS(PANIC2021)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22323/1.380.0106","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the central region of the ATLAS experiment at the LHC. This sampling device uses steel plates as an absorber and scintillating tiles as the active medium. Its response is calibrated to the electromagnetic scale by means of several dedicated calibration systems. The accurate time calibration is important for the energy reconstruction, non-collision background removal as well as for specific physics analyses. The time calibration as performed with collision data is presented. Its monitoring with laser system and collision data is discussed as well and the corrections for various identified problems. Finally, the time resolution as measured with jets in Run 2 is presented.
ATLAS瓷砖量热计的时间校准和监控
瓦式量热计(TileCal)是覆盖在大型强子对撞机ATLAS实验中心区域的强子量热计。该取样装置采用钢板作为吸收剂,闪烁瓦作为有效介质。它的响应通过几个专用的校准系统校准到电磁标度。精确的时间标定对于能量重建、非碰撞背景去除以及具体的物理分析都具有重要意义。给出了用碰撞数据进行时间标定的方法。讨论了用激光系统和碰撞数据对其进行监测,并对发现的各种问题进行了修正。最后,给出了运行2中用射流测量的时间分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信