Hongyang Zhang, L. Angquist, S. Norrga, H. Nee, S. Ostlund
{"title":"Benchmark of high-power STATCOM topologies for flicker compensation","authors":"Hongyang Zhang, L. Angquist, S. Norrga, H. Nee, S. Ostlund","doi":"10.1109/EPE.2016.7695478","DOIUrl":null,"url":null,"abstract":"The current from an electrical arc furnace (EAF) in a steel plant is highly unsymmetrical, i.e. it comprises a large amount of negative sequence. This causes problems with the voltage stability in the capacitor submodules for a static synchronous compensator (STATCOM), when implemented using the modular multilevel converter (M2C) concept. In order to counteract the uncontrollability of the capacitor voltage, a common practice is to circulate a zero-sequence fundamental current or a direct current. The method brings the benefit of re-balancing the active power among the individual phases while it requires over-rating of the valve current or dc voltage of the STATCOM. This would in practice give a more expensive design. This paper presents a benchmark of various M2C-based STATCOM designs considering the valve overrating. The STATCOM topologies will be benchmarked with the EAF modeled for all possible combinations of positive- and negative-sequence current. The rating comparison considering the dc capacitor ripple and zero-sequence harmonic injection are discussed.","PeriodicalId":119358,"journal":{"name":"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE.2016.7695478","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
The current from an electrical arc furnace (EAF) in a steel plant is highly unsymmetrical, i.e. it comprises a large amount of negative sequence. This causes problems with the voltage stability in the capacitor submodules for a static synchronous compensator (STATCOM), when implemented using the modular multilevel converter (M2C) concept. In order to counteract the uncontrollability of the capacitor voltage, a common practice is to circulate a zero-sequence fundamental current or a direct current. The method brings the benefit of re-balancing the active power among the individual phases while it requires over-rating of the valve current or dc voltage of the STATCOM. This would in practice give a more expensive design. This paper presents a benchmark of various M2C-based STATCOM designs considering the valve overrating. The STATCOM topologies will be benchmarked with the EAF modeled for all possible combinations of positive- and negative-sequence current. The rating comparison considering the dc capacitor ripple and zero-sequence harmonic injection are discussed.