A Study on Modeling and Verification of the Percentage Differential Relay for the Protection of AC Electric Railway Feeding System

G. Cho, Min-Sung Kim, Dong-Hyun Kim, Chul-Hwan Kim
{"title":"A Study on Modeling and Verification of the Percentage Differential Relay for the Protection of AC Electric Railway Feeding System","authors":"G. Cho, Min-Sung Kim, Dong-Hyun Kim, Chul-Hwan Kim","doi":"10.1109/TENCON.2018.8650244","DOIUrl":null,"url":null,"abstract":"In general, a Scott-transformer is used to supply the single-phase power for the Korean AC electric railway feeding system. In particular, the Korean Autotransformer feeding system has a different configuration compared to those of other countries, therefore, it has certain distinctive characteristics. In addition, a percentage differential relay is widely and globally utilized for protecting the transformers. However, detailed modeling and simulation for the relay protecting the Korean AC electric railway feeding system is not performed enough. Thus, in this paper, we modeled and verified the percentage differential relay for AC electric railway feeding system by using PSCAD/EMTDC. A simple method to prevent malfunction due to a saturation of the current transformer is suggested as well.","PeriodicalId":132900,"journal":{"name":"TENCON 2018 - 2018 IEEE Region 10 Conference","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"TENCON 2018 - 2018 IEEE Region 10 Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TENCON.2018.8650244","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In general, a Scott-transformer is used to supply the single-phase power for the Korean AC electric railway feeding system. In particular, the Korean Autotransformer feeding system has a different configuration compared to those of other countries, therefore, it has certain distinctive characteristics. In addition, a percentage differential relay is widely and globally utilized for protecting the transformers. However, detailed modeling and simulation for the relay protecting the Korean AC electric railway feeding system is not performed enough. Thus, in this paper, we modeled and verified the percentage differential relay for AC electric railway feeding system by using PSCAD/EMTDC. A simple method to prevent malfunction due to a saturation of the current transformer is suggested as well.
交流电力铁路馈电系统百分率差动继电器的建模与验证研究
韩国的交流电力铁路馈电系统一般采用斯科特变压器单相供电。特别是,韩国的自耦变压器馈电系统与其他国家的配置不同,因此具有一定的鲜明特点。此外,百分率差动继电器在全球范围内广泛应用于变压器保护。然而,对韩国交流电力铁路馈电系统的继电保护进行了详细的建模和仿真。因此,本文采用PSCAD/EMTDC对交流电力铁路馈电系统的百分比差动继电器进行了建模和验证。本文还提出了一种防止电流互感器饱和引起的故障的简单方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信