The Effect of Beams' Orientations on the Intensity-Modulated Radiation TherapyPlan Quality

E. Attalla, I. El-Desoky
{"title":"The Effect of Beams' Orientations on the Intensity-Modulated Radiation TherapyPlan Quality","authors":"E. Attalla, I. El-Desoky","doi":"10.4172/2155-9619.1000324","DOIUrl":null,"url":null,"abstract":"Purpose: The work aims at studying forty Intensity-modulated radiation therapy (IMRT) plans designed using KonRad system and evaluating each of them under different conditions to study the effect of beams' orientations on the plan quality. \nMethods: Clinical step-and-shoot IMRT treatment plans were designed for twenty patients, suffering from different types of non-CNS solid tumors, to be delivery on a Siemens Oncor accelerator with multi-leaf collimators MLCs (82 leaf). To ensure that the similarity or difference between the plans was due to effect of beams' orientations, the same optimization constraints were applied for each plan and all other parameters were kept constant. \nResults: The analysis of performance was based on isodose distributions, Dose Volume Histograms (DVHs) for Planning Target Volume (PTV), the relevant Organs at Risk (OARs) as well as several physical indices like mean dose (Dmean), maximum dose (Dmax), 95% dose (D95), integral dose, volume of tumor receiving 2 Gy and 5 Gy, total number of segments and monitor units (MUs). Homogeneity index and conformation number were two other evaluation parameters that were considered in this study. \nConclusion: All coplanar CP and non-coplanar NC techniques result in clinically acceptable plans, with comparable target doses and dose to critical organs within prescribed dose constraints. For different organs at risk, the coplanar IMRT, the greatest advantage of non-coplanar IMRT was the marked reduction of general trend was that non-coplanar plans achieved the lowest values, while coplanar plans showed the highest. Significant differences (P<0.05) exist only between the homogeneity index HI (1.092 and 1.088) and Monitor Unit MU (357.79 and 341.80) of CP and NC plans respectively. Compared with the integral dose (p=0.007).","PeriodicalId":302578,"journal":{"name":"Journal of Nuclear Medicine and Radiation Therapy","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nuclear Medicine and Radiation Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2155-9619.1000324","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The work aims at studying forty Intensity-modulated radiation therapy (IMRT) plans designed using KonRad system and evaluating each of them under different conditions to study the effect of beams' orientations on the plan quality. Methods: Clinical step-and-shoot IMRT treatment plans were designed for twenty patients, suffering from different types of non-CNS solid tumors, to be delivery on a Siemens Oncor accelerator with multi-leaf collimators MLCs (82 leaf). To ensure that the similarity or difference between the plans was due to effect of beams' orientations, the same optimization constraints were applied for each plan and all other parameters were kept constant. Results: The analysis of performance was based on isodose distributions, Dose Volume Histograms (DVHs) for Planning Target Volume (PTV), the relevant Organs at Risk (OARs) as well as several physical indices like mean dose (Dmean), maximum dose (Dmax), 95% dose (D95), integral dose, volume of tumor receiving 2 Gy and 5 Gy, total number of segments and monitor units (MUs). Homogeneity index and conformation number were two other evaluation parameters that were considered in this study. Conclusion: All coplanar CP and non-coplanar NC techniques result in clinically acceptable plans, with comparable target doses and dose to critical organs within prescribed dose constraints. For different organs at risk, the coplanar IMRT, the greatest advantage of non-coplanar IMRT was the marked reduction of general trend was that non-coplanar plans achieved the lowest values, while coplanar plans showed the highest. Significant differences (P<0.05) exist only between the homogeneity index HI (1.092 and 1.088) and Monitor Unit MU (357.79 and 341.80) of CP and NC plans respectively. Compared with the integral dose (p=0.007).
光束方向对调强放疗计划质量的影响
目的:研究采用KonRad系统设计的40个调强放疗方案,并在不同条件下对每一个调强放疗方案进行评价,研究光束方向对方案质量的影响。方法:对20例不同类型非中枢神经系统实体瘤患者设计临床分步放疗治疗方案,采用西门子Oncor加速器多叶准直MLCs(82叶)输送。为了确保方案之间的相似或差异是由于梁的方向的影响,对每个方案应用相同的优化约束,并保持所有其他参数不变。结果:根据等剂量分布、计划靶体积(PTV)的剂量体积直方图(DVHs)、相关危险器官(OARs)以及平均剂量(Dmean)、最大剂量(Dmax)、95%剂量(D95)、积分剂量、接受2 Gy和5 Gy肿瘤体积、总节段数和监测单位(MUs)等物理指标进行性能分析。同质性指数和构象数是本研究考虑的另外两个评价参数。结论:所有共面CP和非共面NC技术均可获得临床可接受的方案,在规定的剂量限制下,靶剂量和关键器官剂量相当。对于不同的危险器官,共面IMRT,非共面IMRT的最大优势是总体趋势的显著降低,其中非共面IMRT达到最低值,而共面IMRT达到最高值。CP和NC方案的均匀性指数HI分别为1.092和1.088,监测单元MU分别为357.79和341.80,差异均有统计学意义(P<0.05)。与积分剂量比较(p=0.007)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信