Wireless Distributed Control with Open-Phase Fault-Tolerance for Delta-Connected Three-Phase Three-Wire Solid-State Transformers

Keita Ohata, Koki Yamanokuchi, Jun-ichi Itoh
{"title":"Wireless Distributed Control with Open-Phase Fault-Tolerance for Delta-Connected Three-Phase Three-Wire Solid-State Transformers","authors":"Keita Ohata, Koki Yamanokuchi, Jun-ichi Itoh","doi":"10.23919/ICPE2023-ECCEAsia54778.2023.10213576","DOIUrl":null,"url":null,"abstract":"This paper proposes wireless distributed control with a fault-tolerant for a solid-state transformer (SST) in single-wire open fault. A voltage imbalance occurs at the input side of each cell in the SST when an open-phase fault occurs. The voltage imbalance causes overmodulation in the power factor correction (PFC) converter. The proposed method employs the current droop control as an autonomous distributed control to achieve the voltage balance of each cell and prevent overmodulation without communication among each cell. The proposed method reduces the imbalance of the input voltage among series-connected cells by up to 95% compared to the control without the current droop control. Moreover, continuous operation is achieved during single-wire open-phase faults.","PeriodicalId":151155,"journal":{"name":"2023 11th International Conference on Power Electronics and ECCE Asia (ICPE 2023 - ECCE Asia)","volume":"124 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 11th International Conference on Power Electronics and ECCE Asia (ICPE 2023 - ECCE Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/ICPE2023-ECCEAsia54778.2023.10213576","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper proposes wireless distributed control with a fault-tolerant for a solid-state transformer (SST) in single-wire open fault. A voltage imbalance occurs at the input side of each cell in the SST when an open-phase fault occurs. The voltage imbalance causes overmodulation in the power factor correction (PFC) converter. The proposed method employs the current droop control as an autonomous distributed control to achieve the voltage balance of each cell and prevent overmodulation without communication among each cell. The proposed method reduces the imbalance of the input voltage among series-connected cells by up to 95% compared to the control without the current droop control. Moreover, continuous operation is achieved during single-wire open-phase faults.
三角连接三相三线固态变压器开相容错无线分布式控制
针对固态变压器单线开路故障,提出了一种具有容错能力的无线分布式控制方法。当发生开相故障时,在海表温度的每个单元的输入侧会出现电压不平衡。电压不平衡导致功率因数校正(PFC)变换器过调制。该方法采用电流下垂控制作为一种自治的分布式控制,在不通信的情况下实现各单元的电压平衡,防止过调制。与不采用电流下垂控制的控制相比,该方法可将串联电池间输入电压的不平衡降低95%。此外,在单线断相故障时,可以实现连续运行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信