{"title":"Electrical conductivity of kerosene by DC measurement","authors":"Y. Matsubara","doi":"10.1109/CEIDP.2000.885276","DOIUrl":null,"url":null,"abstract":"Although the conductivity is underlying characteristic of petroleum liquids, there is an inconsistency on recommended procedure of conductivity measurement. Conductivity of petroleum liquids measured by DC methods is time dependent, and it also depends upon electrode configuration and applied voltage. Hence, it is required to look into the phenomena a little far, in order to decide which conductivity could be adopted as an indicator to evaluate the electrostatic risk during the handling of hydrocarbon liquids. The author measured the conductivity of kerosene with electrodes of parallel disk configuration. The time course of the conduction current are compared and the criteria for the reliable measurement is presented.","PeriodicalId":414762,"journal":{"name":"2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2000.885276","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Although the conductivity is underlying characteristic of petroleum liquids, there is an inconsistency on recommended procedure of conductivity measurement. Conductivity of petroleum liquids measured by DC methods is time dependent, and it also depends upon electrode configuration and applied voltage. Hence, it is required to look into the phenomena a little far, in order to decide which conductivity could be adopted as an indicator to evaluate the electrostatic risk during the handling of hydrocarbon liquids. The author measured the conductivity of kerosene with electrodes of parallel disk configuration. The time course of the conduction current are compared and the criteria for the reliable measurement is presented.
直流测量煤油电导率
虽然电导率是石油液体的基本特征,但电导率测量的推荐方法却不一致。用直流方法测量石油液体的电导率与时间有关,还取决于电极的结构和施加的电压。因此,需要对这一现象进行深入的研究,以确定哪种电导率可以作为评价烃类液体处理过程中静电风险的指标。采用平行圆盘结构的电极测量了煤油的电导率。比较了导通电流的时间过程,提出了可靠测量的准则。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信