A phantom for cadaverless evaluation of targeting systems for distal locking of intramedullary nails

Fadi T. Jaber, Awni B. Al-Jayyousi
{"title":"A phantom for cadaverless evaluation of targeting systems for distal locking of intramedullary nails","authors":"Fadi T. Jaber, Awni B. Al-Jayyousi","doi":"10.1109/MECBME.2014.6783219","DOIUrl":null,"url":null,"abstract":"One of the most challenging parts of intramedullary nailing is finding the location of the distal holes of the intramedullary nail following its insertion along the medullary canal. The preferred method for locating the distal holes involves the use of x-ray imaging. In order to reduce the exposure of the medical personnel and patient to ionizing radiation several alternative methods are being investigated and their feasibility and accuracy are being assessed by performing surgery on cadavers. Due to several issues associated with cadavers, this paper introduces a phantom as an alternative tool for the evaluation of such techniques. The features associated with this phantom should allow researchers to assess the performance of their distal locking systems at a reduced cost and without the need for surgical skills.","PeriodicalId":384055,"journal":{"name":"2nd Middle East Conference on Biomedical Engineering","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2nd Middle East Conference on Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MECBME.2014.6783219","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

One of the most challenging parts of intramedullary nailing is finding the location of the distal holes of the intramedullary nail following its insertion along the medullary canal. The preferred method for locating the distal holes involves the use of x-ray imaging. In order to reduce the exposure of the medical personnel and patient to ionizing radiation several alternative methods are being investigated and their feasibility and accuracy are being assessed by performing surgery on cadavers. Due to several issues associated with cadavers, this paper introduces a phantom as an alternative tool for the evaluation of such techniques. The features associated with this phantom should allow researchers to assess the performance of their distal locking systems at a reduced cost and without the need for surgical skills.
用于髓内钉远端锁定靶系统无尸体评估的模型
髓内钉最具挑战性的部分之一是在髓内钉沿髓管插入后找到髓内钉远端孔的位置。定位远端孔的首选方法包括使用x射线成像。为了减少医务人员和病人对电离辐射的暴露,正在研究几种替代方法,并通过对尸体进行手术来评估其可行性和准确性。由于与尸体相关的几个问题,本文介绍了一个幻影作为评估这种技术的替代工具。该假体的相关特征使研究人员能够以更低的成本评估远端锁定系统的性能,并且不需要手术技能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信