Modification of an EMP Facility to Support Threshold Testing of Electronic Systems

F. Peterkin, J. Hebert, D. Stoudt, J. Latess
{"title":"Modification of an EMP Facility to Support Threshold Testing of Electronic Systems","authors":"F. Peterkin, J. Hebert, D. Stoudt, J. Latess","doi":"10.1109/PPC.2005.300772","DOIUrl":null,"url":null,"abstract":"The naval ordnance transient electromagnetic simulator (NOTES) is a bounded wave test facility located at the Naval Surface Warfare Center, Dahlgren Division (NSWCDD). NOTES was designed to enable standardized electromagnetic pulse (EMP) testing, but in order to support tests to assess the vulnerability of US infrastructure to High-altitude EMP (HEMP) it was modified to enable threshold testing with peak amplitudes of 1 kV/m up to 100 kV/m while maintaining nominally the same temporal characteristics of the threat waveform. The range of amplitude was accomplished using three different voltage pulser configurations which provided nearly continuous variability. This paper provides a detailed description of the NOTES facility and the design, implementation, and results of these modifications. We present the waveforms that were used during testing and show that they provided a consistent stimulus both in terms of the overall waveform shape and in the critical risetime characteristic.","PeriodicalId":200159,"journal":{"name":"2005 IEEE Pulsed Power Conference","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 IEEE Pulsed Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.2005.300772","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The naval ordnance transient electromagnetic simulator (NOTES) is a bounded wave test facility located at the Naval Surface Warfare Center, Dahlgren Division (NSWCDD). NOTES was designed to enable standardized electromagnetic pulse (EMP) testing, but in order to support tests to assess the vulnerability of US infrastructure to High-altitude EMP (HEMP) it was modified to enable threshold testing with peak amplitudes of 1 kV/m up to 100 kV/m while maintaining nominally the same temporal characteristics of the threat waveform. The range of amplitude was accomplished using three different voltage pulser configurations which provided nearly continuous variability. This paper provides a detailed description of the NOTES facility and the design, implementation, and results of these modifications. We present the waveforms that were used during testing and show that they provided a consistent stimulus both in terms of the overall waveform shape and in the critical risetime characteristic.
修改电磁脉冲设施以支持电子系统的阈值测试
海军军械瞬变电磁模拟器(NOTES)是位于海军水面作战中心Dahlgren分部(NSWCDD)的一个有界波测试设施。NOTES旨在实现标准化电磁脉冲(EMP)测试,但为了支持评估美国基础设施对高空EMP (HEMP)脆弱性的测试,它被修改为能够进行峰值幅度为1千伏/米至100千伏/米的阈值测试,同时名义上保持威胁波形的相同时间特征。振幅范围是通过三种不同的电压脉冲发生器配置来实现的,这些配置提供了几乎连续的可变性。本文详细描述了NOTES功能以及这些修改的设计、实现和结果。我们展示了在测试中使用的波形,并表明它们在整体波形形状和临界上升时间特性方面提供了一致的刺激。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信