Prediction of remaining battery discharge time in telecommunications systems

T. Matsushima, S. Ishizuka, M. Hashiwaki
{"title":"Prediction of remaining battery discharge time in telecommunications systems","authors":"T. Matsushima, S. Ishizuka, M. Hashiwaki","doi":"10.1109/INTLEC.1990.171301","DOIUrl":null,"url":null,"abstract":"A telecommunications power system is always equipped with a standby power source, usually rechargeable lead acid batteries. However, predicting the remaining discharge time during the course of actual battery discharge has not yet been attempted. The authors introduce and demonstrate a useful calculation method, in which the load current profile is divided into equal short time units. This allows the total reserve time of the battery to be calculated by deducting the integrated amount of electricity in ampere-hours from the available ones. Then, the remaining discharge time can be calculated by subtracting the elapsed time during AC failure. In the integration process, the amount in each time unit is transformed into a value equivalent to a 10-hour rate discharge by using the coefficient introduced in this study. This method is examined by applying it to several load current profiles including actual ones from telephone offices, and the results show prediction error to be +or-5%.<<ETX>>","PeriodicalId":264940,"journal":{"name":"12th International Conference on Telecommunications Energy","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1990-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"12th International Conference on Telecommunications Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.1990.171301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

A telecommunications power system is always equipped with a standby power source, usually rechargeable lead acid batteries. However, predicting the remaining discharge time during the course of actual battery discharge has not yet been attempted. The authors introduce and demonstrate a useful calculation method, in which the load current profile is divided into equal short time units. This allows the total reserve time of the battery to be calculated by deducting the integrated amount of electricity in ampere-hours from the available ones. Then, the remaining discharge time can be calculated by subtracting the elapsed time during AC failure. In the integration process, the amount in each time unit is transformed into a value equivalent to a 10-hour rate discharge by using the coefficient introduced in this study. This method is examined by applying it to several load current profiles including actual ones from telephone offices, and the results show prediction error to be +or-5%.<>
电信系统中电池剩余放电时间的预测
电讯电力系统总是配备备用电源,通常是可充电的铅酸电池。然而,在实际的电池放电过程中预测剩余的放电时间还没有尝试过。作者介绍并论证了一种实用的计算方法,该方法将负载电流分布划分为相等的短时间单元。这允许通过从可用电量中扣除以安培小时为单位的综合电量来计算电池的总备用时间。然后,剩余的放电时间可以通过减去在交流故障期间经过的时间来计算。在积分过程中,利用本文引入的系数,将每个时间单位内的电量换算成一个相当于10小时放电速率的数值。将该方法应用于多个负荷电流分布(包括电话局的实际负荷电流分布)进行了检验,结果表明预测误差在±5%之间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信