Optimization of Injection Conditions in Preparative Liquid Chromatography

G. Crétier, J. Rocca
{"title":"Optimization of Injection Conditions in Preparative Liquid Chromatography","authors":"G. Crétier, J. Rocca","doi":"10.1080/01496398708057618","DOIUrl":null,"url":null,"abstract":"Abstract This paper describes the effect of injection volume on injectable sample load consistent with purity and recovery ratio of the solute of interest for different shapes of solute isotherms (convex or concave, without or with interactions between two adjacent solute bands). In preparative liquid chromatography, the column mass overloading conditions are usually thought to be better than volume overload conditions; according to this study, this statement is shown not to be true in all cases because optimization of injection conditions is much more complicated. For some isotherm shapes, there is an optimal injection volume in which injectable sample load is maximum.","PeriodicalId":184327,"journal":{"name":"Preparative-Scale Chromatography","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1987-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Preparative-Scale Chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/01496398708057618","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Abstract This paper describes the effect of injection volume on injectable sample load consistent with purity and recovery ratio of the solute of interest for different shapes of solute isotherms (convex or concave, without or with interactions between two adjacent solute bands). In preparative liquid chromatography, the column mass overloading conditions are usually thought to be better than volume overload conditions; according to this study, this statement is shown not to be true in all cases because optimization of injection conditions is much more complicated. For some isotherm shapes, there is an optimal injection volume in which injectable sample load is maximum.
制备液相色谱进样条件的优化
摘要本文描述了不同形状的溶质等温线(凸型或凹型,无或有两个相邻溶质带之间的相互作用)下,注射体积对符合所研究溶质纯度和回收率的可注射样品负荷的影响。在制备型液相色谱中,通常认为柱质量过载条件优于体积过载条件;根据这项研究,这种说法并不适用于所有情况,因为优化注入条件要复杂得多。对于某些等温线形状,存在可注射样品负载最大的最佳进样量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信