Y Kumagai, T Shiga, K Sunaga, G Cornélissen, A Ebihara, F Halberg
{"title":"Usefulness of circadian amplitude of blood pressure in predicting hypertensive cardiac involvement.","authors":"Y Kumagai, T Shiga, K Sunaga, G Cornélissen, A Ebihara, F Halberg","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Twenty-four-hour blood pressure (BP) profiles of 56 patients diagnosed as 'hypertensive' by WHO criteria were analyzed by the fit of a 24-hour cosine curve according to the single cosinor method. A left ventricular mass index (LVMI) was also assessed by two-dimensional echocardiography on each patient as a gauge of target organ involvement. LVMI and the BP MESOR correlates positively for systolic, S (r = 0.324), mean arterial, MA (r = 0.334) and diastolic, D (r = 0.267) BP (P less than 0.05), yet no statistically significant linear correlation between LVMI and the circadian BP amplitude (one-half of predictable change) was found. When a second-degree polynomial regression was fitted to the circadian BP amplitudes, an association was found (SBP: R2 = 0.138, P = 0.02; MAP: R2 = 0.167, P = 0.01; DBP: R2 = 0.128, P less than 0.01). The corresponding curves were characterized by peaks in the circadian amplitudes of SBP, MAP and DBP around a value of LVMI between 110 and 120 g/m2. For further scrutiny, three subgroups had been formed on the basis of literature, a priori with respect to the LVMI (group 1: LVMI less than 100); group 2: 100 less than LVMI less than 130; group 3: 130 less than LVMI). For MESORs, there was no difference between groups 1 and 2, whereas the MESOR of group 3 were larger than the other two groups. The circadian BP amplitudes of group 2 were larger than those of the other two groups for SBP, MAP and DBP. An increasing LVMI precedes a definitive increase of BP MESOR and coincides with an increase in the circadian BP amplitude; thus an increase in extent of circadian changes can alert the self-monitoring population of a target organ involvement.</p>","PeriodicalId":75705,"journal":{"name":"Chronobiologia","volume":"19 1-2","pages":"43-58"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chronobiologia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Twenty-four-hour blood pressure (BP) profiles of 56 patients diagnosed as 'hypertensive' by WHO criteria were analyzed by the fit of a 24-hour cosine curve according to the single cosinor method. A left ventricular mass index (LVMI) was also assessed by two-dimensional echocardiography on each patient as a gauge of target organ involvement. LVMI and the BP MESOR correlates positively for systolic, S (r = 0.324), mean arterial, MA (r = 0.334) and diastolic, D (r = 0.267) BP (P less than 0.05), yet no statistically significant linear correlation between LVMI and the circadian BP amplitude (one-half of predictable change) was found. When a second-degree polynomial regression was fitted to the circadian BP amplitudes, an association was found (SBP: R2 = 0.138, P = 0.02; MAP: R2 = 0.167, P = 0.01; DBP: R2 = 0.128, P less than 0.01). The corresponding curves were characterized by peaks in the circadian amplitudes of SBP, MAP and DBP around a value of LVMI between 110 and 120 g/m2. For further scrutiny, three subgroups had been formed on the basis of literature, a priori with respect to the LVMI (group 1: LVMI less than 100); group 2: 100 less than LVMI less than 130; group 3: 130 less than LVMI). For MESORs, there was no difference between groups 1 and 2, whereas the MESOR of group 3 were larger than the other two groups. The circadian BP amplitudes of group 2 were larger than those of the other two groups for SBP, MAP and DBP. An increasing LVMI precedes a definitive increase of BP MESOR and coincides with an increase in the circadian BP amplitude; thus an increase in extent of circadian changes can alert the self-monitoring population of a target organ involvement.