{"title":"Automating the determination of wave speed using the PU-loop method","authors":"M. Swalen, A. Khir","doi":"10.1109/CIC.2005.1588099","DOIUrl":null,"url":null,"abstract":"The PU-loop (pressure-velocity loop) is a method for determining wave speed and relies on the linear relationship between the pressure and velocity in the absence of reflected waves. This linearity of the PU-loop during early systole, which is directly related to wave speed, has always been established by eye. This paper presents a new technique that establishes this linearity and thus determining wave speed online. Pressure and flow were measured in the ascending aorta of 11 anesthetised dogs. The slope of the PU-loop, indicating wave speed was determined by eye and by using the new technique. The difference between the slopes of the two methods is in the order of 3%. The new technique is convenient and allows for the online assessment of wave speed, which could be used as a bedside tool for the assessment of arterial compliance","PeriodicalId":239491,"journal":{"name":"Computers in Cardiology, 2005","volume":"86 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers in Cardiology, 2005","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2005.1588099","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The PU-loop (pressure-velocity loop) is a method for determining wave speed and relies on the linear relationship between the pressure and velocity in the absence of reflected waves. This linearity of the PU-loop during early systole, which is directly related to wave speed, has always been established by eye. This paper presents a new technique that establishes this linearity and thus determining wave speed online. Pressure and flow were measured in the ascending aorta of 11 anesthetised dogs. The slope of the PU-loop, indicating wave speed was determined by eye and by using the new technique. The difference between the slopes of the two methods is in the order of 3%. The new technique is convenient and allows for the online assessment of wave speed, which could be used as a bedside tool for the assessment of arterial compliance