[The stereognathograph PC--test results with the new version of the device].

H Fischer-Brandies, G Kluge, R Burckhardt
{"title":"[The stereognathograph PC--test results with the new version of the device].","authors":"H Fischer-Brandies,&nbsp;G Kluge,&nbsp;R Burckhardt","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The PC stereognathograph was investigated for measurement errors in laboratory experiments on an optical bench as well as on an articulator. The values obtained were compared with the data of the predecessor model. A substantial reduction in the linearity in transverse measurements has been effected, so that these are now within acceptable limits. A variation of linearity factors which can be avoided by electronic fine adjustment still arises owing to incongruence of the six measurement channels. The hinge axis can be localized very well on the articulator. By and large, the announced correction of the projection error which we have demanded has not been implemented up to now. In view of the clear imaging of condylar movement in space and time on the monitor and the adequate precision of the clinical measurements effected, the PC stereognathograph appears to be a valuable system for instrumental diagnostics.</p>","PeriodicalId":77104,"journal":{"name":"Deutsche Zahn-, Mund-, und Kieferheilkunde mit Zentralblatt","volume":"80 1","pages":"21-3"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Deutsche Zahn-, Mund-, und Kieferheilkunde mit Zentralblatt","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The PC stereognathograph was investigated for measurement errors in laboratory experiments on an optical bench as well as on an articulator. The values obtained were compared with the data of the predecessor model. A substantial reduction in the linearity in transverse measurements has been effected, so that these are now within acceptable limits. A variation of linearity factors which can be avoided by electronic fine adjustment still arises owing to incongruence of the six measurement channels. The hinge axis can be localized very well on the articulator. By and large, the announced correction of the projection error which we have demanded has not been implemented up to now. In view of the clear imaging of condylar movement in space and time on the monitor and the adequate precision of the clinical measurements effected, the PC stereognathograph appears to be a valuable system for instrumental diagnostics.

【立体式PC机——新版本设备的测试结果】。
在光学实验台上和关节器上研究了PC立体照相仪的测量误差。将所得值与之前模型的数据进行了比较。横向测量的线性度已经大大降低,因此现在这些都在可接受的范围内。由于六个测量通道的不一致,仍然会产生可以通过电子微调避免的线性因素的变化。铰链轴可以很好地定位在关节上。总的说来,我们所要求的公布的对投影误差的修正,到目前为止还没有得到执行。鉴于显示器上髁突运动在空间和时间上的清晰成像以及临床测量的足够精度,PC立体成像似乎是一种有价值的仪器诊断系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信