{"title":"Parallel redundant operation of UPS with robust current minor loop","authors":"Y. Ito, O. Iyama","doi":"10.1109/PCCON.1997.645660","DOIUrl":null,"url":null,"abstract":"This paper describes a control method of UPS inverters connected in parallel. The UPS output voltage is controlled by an algorithm with an inverter current. A minor loop using two types of observers. Only the following two points are added to the algorithm for realizing parallel operations: (1) feedback of a common load current instead of the UPS output current; and (2) adjusting the phase of the output voltage to make the reactive component of the circulating currents zero. The proposed method has the following features, compared with conventional methods; (1) it does not need an additional output voltage control for parallel operation; (2) the impedances among UPSs are resistive so that the circulating currents caused by phase difference among UPSs have only reactive components; and (3) increase of software for parallel operation control is minimal.","PeriodicalId":262154,"journal":{"name":"Proceedings of Power Conversion Conference - PCC '97","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"31","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Power Conversion Conference - PCC '97","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCCON.1997.645660","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 31
Abstract
This paper describes a control method of UPS inverters connected in parallel. The UPS output voltage is controlled by an algorithm with an inverter current. A minor loop using two types of observers. Only the following two points are added to the algorithm for realizing parallel operations: (1) feedback of a common load current instead of the UPS output current; and (2) adjusting the phase of the output voltage to make the reactive component of the circulating currents zero. The proposed method has the following features, compared with conventional methods; (1) it does not need an additional output voltage control for parallel operation; (2) the impedances among UPSs are resistive so that the circulating currents caused by phase difference among UPSs have only reactive components; and (3) increase of software for parallel operation control is minimal.