{"title":"Dynamic analysis of three-level voltage-source inverters applied to power regulation","authors":"S. Alepuz, J. Bordonau, J. Peracaula","doi":"10.1109/PESC.1999.785589","DOIUrl":null,"url":null,"abstract":"The dynamic characteristics of three-level voltage-source inverters are analyzed, in order to control the power delivered to the load in closed-loop operation. A model of the three-level voltage-source inverter is presented. The dynamics of the complete system is considered, including the DC-link and the load side. The model uses D-Q transformation. An open-loop dynamic analysis is done first. An LQR controller is designed to improve the dynamic response of the system for the closed-loop operation. The simulation results confirm the improvement of dynamic behavior in closed-loop operation.","PeriodicalId":292317,"journal":{"name":"30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1999.785589","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

The dynamic characteristics of three-level voltage-source inverters are analyzed, in order to control the power delivered to the load in closed-loop operation. A model of the three-level voltage-source inverter is presented. The dynamics of the complete system is considered, including the DC-link and the load side. The model uses D-Q transformation. An open-loop dynamic analysis is done first. An LQR controller is designed to improve the dynamic response of the system for the closed-loop operation. The simulation results confirm the improvement of dynamic behavior in closed-loop operation.
应用于功率调节的三电平电压逆变器的动态分析
分析了三电平电压源逆变器的动态特性,以便在闭环运行状态下控制输出给负载的功率。提出了一种三电平电压源逆变器的模型。考虑了整个系统的动力学,包括直流链路和负载侧。该模型使用D-Q变换。首先进行了开环动力学分析。设计了LQR控制器,以改善系统在闭环运行时的动态响应。仿真结果证实了闭环运行时动态性能的改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信