{"title":"Dynamic analysis of three-level voltage-source inverters applied to power regulation","authors":"S. Alepuz, J. Bordonau, J. Peracaula","doi":"10.1109/PESC.1999.785589","DOIUrl":null,"url":null,"abstract":"The dynamic characteristics of three-level voltage-source inverters are analyzed, in order to control the power delivered to the load in closed-loop operation. A model of the three-level voltage-source inverter is presented. The dynamics of the complete system is considered, including the DC-link and the load side. The model uses D-Q transformation. An open-loop dynamic analysis is done first. An LQR controller is designed to improve the dynamic response of the system for the closed-loop operation. The simulation results confirm the improvement of dynamic behavior in closed-loop operation.","PeriodicalId":292317,"journal":{"name":"30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1999.785589","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15
Abstract
The dynamic characteristics of three-level voltage-source inverters are analyzed, in order to control the power delivered to the load in closed-loop operation. A model of the three-level voltage-source inverter is presented. The dynamics of the complete system is considered, including the DC-link and the load side. The model uses D-Q transformation. An open-loop dynamic analysis is done first. An LQR controller is designed to improve the dynamic response of the system for the closed-loop operation. The simulation results confirm the improvement of dynamic behavior in closed-loop operation.