{"title":"Improved MRAS based HI extraction method for PMSM of Electro-Mechanical Actuator","authors":"Yujie Zhang, Liansheng Liu, Datong Liu, Yu Peng","doi":"10.1109/phm-qingdao46334.2019.8943022","DOIUrl":null,"url":null,"abstract":"Electro-Mechanical Actuator (EMA) utilized in the flight control actuation is becoming more and more important in aerospace applications, especially for more electric aircraft. EMA Health Indicator (HI) extraction is challenging as the sensor installation is limited, which is a critical part of EMA Prognostics and Health Management (PHM). Model Reference Adaptive System (MRAS) is an effective parameter estimation method to extract HIs of Permanent Magnet Synchronous Motor (PMSM) of EMA, which can achieve high precision estimation with a small amount of calculation. However, the MRAS based HI extraction method is not suitable for stator resistance estimation of PMSM with Field-Oriented Control (FOC) strategy in which the expected d-axis current is zero. Hence, to deal with this problem, an improved MRAS is proposed for the HI extraction of stator resistance of EMA PMSM. In the proposed HI extraction method, the expected d-axis current of PMSM is set to a constant nearly zero, and the inputs of d-axis current of MRAS is substituted by the sum of a constant and d-axis current. Besides, the structure of adjustable model of MRAS is improved to cope with this sum. Furthermore, the estimated stator resistance based on improved MRAS, which is a useful HI for EMA PMSM, can be obtained. To evaluate the effectiveness of HI extraction method based on improved MRAS for EMA PMSM, two experiments are carried out using simulation data. The experimental results demonstrate that the improved MRAS based method is more suitable for HI extraction of EMA PMSM.","PeriodicalId":259179,"journal":{"name":"2019 Prognostics and System Health Management Conference (PHM-Qingdao)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Prognostics and System Health Management Conference (PHM-Qingdao)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/phm-qingdao46334.2019.8943022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Electro-Mechanical Actuator (EMA) utilized in the flight control actuation is becoming more and more important in aerospace applications, especially for more electric aircraft. EMA Health Indicator (HI) extraction is challenging as the sensor installation is limited, which is a critical part of EMA Prognostics and Health Management (PHM). Model Reference Adaptive System (MRAS) is an effective parameter estimation method to extract HIs of Permanent Magnet Synchronous Motor (PMSM) of EMA, which can achieve high precision estimation with a small amount of calculation. However, the MRAS based HI extraction method is not suitable for stator resistance estimation of PMSM with Field-Oriented Control (FOC) strategy in which the expected d-axis current is zero. Hence, to deal with this problem, an improved MRAS is proposed for the HI extraction of stator resistance of EMA PMSM. In the proposed HI extraction method, the expected d-axis current of PMSM is set to a constant nearly zero, and the inputs of d-axis current of MRAS is substituted by the sum of a constant and d-axis current. Besides, the structure of adjustable model of MRAS is improved to cope with this sum. Furthermore, the estimated stator resistance based on improved MRAS, which is a useful HI for EMA PMSM, can be obtained. To evaluate the effectiveness of HI extraction method based on improved MRAS for EMA PMSM, two experiments are carried out using simulation data. The experimental results demonstrate that the improved MRAS based method is more suitable for HI extraction of EMA PMSM.
基于MRAS的永磁同步电机HI提取方法的改进
用于飞行控制作动的机电作动器(EMA)在航空航天领域的应用越来越重要,尤其是在电动化程度越来越高的飞机上。EMA健康指标(HI)的提取具有挑战性,因为传感器安装有限,这是EMA预后和健康管理(PHM)的关键部分。模型参考自适应系统(MRAS)是一种有效的提取永磁同步电机HIs的参数估计方法,可以用较少的计算量实现高精度的估计。然而,基于MRAS的HI提取方法不适用于磁场定向控制(FOC)策略下d轴电流为零的永磁同步电机定子电阻估计。针对这一问题,提出了一种改进的MRAS方法,用于电磁永磁同步电机定子电阻的HI提取。在所提出的HI提取方法中,将PMSM的期望d轴电流设置为接近于零的常数,并将MRAS的d轴电流输入替换为常数和d轴电流之和。并对MRAS可调模型的结构进行了改进,以应对这一总和。此外,基于改进MRAS的定子电阻估计是EMA永磁同步电机的一个有用的HI。为了评估基于改进MRAS的HI提取方法对EMA PMSM的有效性,利用仿真数据进行了两次实验。实验结果表明,改进的基于MRAS的方法更适合于EMA PMSM的HI提取。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信